Abonnement à la biblothèque: Guest
Journal of Long-Term Effects of Medical Implants

Publication de 4  numéros par an

ISSN Imprimer: 1050-6934

ISSN En ligne: 1940-4379

SJR: 0.184 SNIP: 0.485 CiteScore™:: 1.1 H-Index: 39

Indexed in

Specific Complications of the Mobile-Bearing Total Knee Prosthesis

Volume 19, Numéro 1, 2009, pp. 1-11
DOI: 10.1615/JLongTermEffMedImplants.v19.i1.10
Get accessGet access

RÉSUMÉ

Total knee arthroplasty (TKA) is considered as a standard procedure for the treatment of the severe degenerative knee joint. The outcomes of TKA have improved over the last few decades because of a better understanding of design features and surgical techniques. Contemporary tibial component designs in TKA can be subdivided into two groups (fixed or mobile-bearing) on the basis of different fundamental principles. The mobile-bearing knee is designed with better biomechanical concepts than the fixed-bearing knee, in terms of providing congruity and mobility of tibial bearing. It is expected that the mobile-bearing knee could resolve the problems of component wear and component loosening as seen in fixed-bearing knees. However, the long-term durability of mobile-bearing knees has not been extensively proven to have better outcomes than that of fixed-bearing knees. There are some potential clinical complications of mobile-bearing knees that must be addressed. On the basis of our previous clinical experience and a retrieval analysis, this article summarizes five specific complications including (1) early or late dislocation of the mobile-bearing component, (2) failure or dislodging of the meniscal bearing, (3) hemarthrosis associated with a failure of the meniscal-bearing knee, (4) failure of the patellar component, and (5) higher prevalence of osteolysis. Before taking advantage of mobile bearing, we should consider these specific clinical complications, which were not found in the fixed-bearing TKA.

CITÉ PAR
  1. Magin M.N., „Spin-out“ – eine vermeidbare Komplikation in der Knieendoprothetik, Der Orthopäde, 43, 2, 2014. Crossref

  2. Fransen B. L., van Duijvenbode D. C., Hoozemans M. J. M., Burger B. J., No differences between fixed- and mobile-bearing total knee arthroplasty, Knee Surgery, Sports Traumatology, Arthroscopy, 25, 6, 2017. Crossref

  3. Joldersma Patty, Inleiding: de knieprothese, in Kunstgewrichten: knie en enkel, 2016. Crossref

  4. Arcângelo Joana, Guerra-Pinto Francisco, Pinto André, Grenho André, Navarro Alfons, Martin Oliva Xavier, Peri-prosthetic bone cysts after total ankle replacement. A systematic review and meta-analysis, Foot and Ankle Surgery, 25, 2, 2019. Crossref

  5. Tiwari Vivek, Meshram Prashant, Park Chang Kyu, Bansal Vivek, Kim Tae Kyun, New mobile-bearing TKA with unique ball and socket post-cam mechanism offers similar function and stability with better prosthesis fit and gap balancing compared to an established fixed-bearing prosthesis, Knee Surgery, Sports Traumatology, Arthroscopy, 27, 7, 2019. Crossref

756 Vues d'articles 24 Téléchargements d'articles Métrique
756 VUES 24 TÉLÉCHARGEMENTS 5 Crossref CITATIONS Google
Scholar
CITATIONS

Articles avec un contenu similaire:

Severe Metallosis Following Polyethylene Dislocation in a Mobile-Bearing Medial Unicompartmental Knee Replacement Journal of Long-Term Effects of Medical Implants, Vol.24, 2014, issue 2-3
Ilias Katsougrakis, Rafik Fanous, Enrique Saavedra, Andrew Harrison, Alexandros P. Apostolopoulos
Patients of Obese Representation Require Longer Operative Times: An Evaluation of Acetabular and Pelvic Ring Operative Duration Journal of Long-Term Effects of Medical Implants, Vol.33, 2023, issue 1
Devon Myers, Benjamin C. Taylor, Braden J. Passias, Carina Bertolini, Phillip Myers, Hayden B. Schuette, Satvam Mehta, Robert J. Patterson
Large Diameter Total Hip Replacement for Acute Displaced Femoral Neck Fracture Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 1
James W. Pritchett
10-Year Evaluation of the Cementless Low-Contact- Stress Rotating-Platform Total Knee Arthroplasty Journal of Long-Term Effects of Medical Implants, Vol.19, 2009, issue 4
Vasileios S. Nikolaou, Demetrios S. Korres, Olga D. Savvidou, Panayiotis J. Papagelopoulos, Stergios N. Lallos, Nikolaos E. Efstathopoulos, Andreas F. Mavrogenis
Long-Term Results of a Cementless Knee Prosthesis with a Metal-Backed Patellar Component: Clinical and Radiological Follow-Up with Histology from Retrieved Components Journal of Long-Term Effects of Medical Implants, Vol.13, 2003, issue 4
Mikael Sundfeldt, Tomas Albrektsson, Lars V Carlsson, Carina B. Johansson, Lars Regner

Prochains articles

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections Prix et politiques d'abonnement Begell House Contactez-nous Language English 中文 Русский Português German French Spain