Practice-Based Clinical Evaluation of Dental Implants Placed with Immediate or Delayed Loading Protocols: One-Year Follow-Up

Volume 29, Numéro 2, 2019, pp. 141-149
DOI: 10.1615/JLongTermEffMedImplants.2019031911
Get accessGet access

RÉSUMÉ

We evaluate bone remodeling and prostheses survival of immediately provisionalized with occlusal loading and delayed loading (DL) single implants placed in the posterior region after 1-yr follow-up in dental practices. Included in the study are patients selected to receive one regular implant (4 × 10 mm) for single tooth replacement in healed ridge sockets in the mandible and maxilla. Implants are immediately loaded or delayed functionally loaded with metal ceramic crowns, depending on peak insertion torque value. All implants are clinically and radiographically evaluated at T1, immediately postoperatively; T2, 60 d; T3, 180 d; and T4, 360 d. Measurements between implant platform and top of alveolar bone crest at distal and mesial areas are performed using periapical radiographs. Data are statistically evaluated through two-way repeated measures of analysis of variance following post hoc comparisons using the Tukey test (p < 0.05). Ten specialists working in ten different practices treat 36 patients who receive one implant each with internal conical connection (hybrid implant system, 4 × 10 mm) (Emfils; Itu, Brazil). Results show that bone-level alterations in immediate (IM; 0.56 mm; confidence interval [CI]: ± 0.21 mm) and delayed (0.65 mm; CI: ± 0.19 mm) groups are not significantly different (p = 0.515) during the course of the 1-yr observation period. In both groups, statistically significant progressive bone-level remodeling occurs through the evaluated follow-up time points (p < 0.047). All prostheses are rated "alpha," presenting 100% success at 1-yr follow-up. The loading method does not influence bone-remodeling levels around IM or DL at the posterior region after 1-yr follow-up. No prostheses complications are reported.

RÉFÉRENCES
  1. Zarandi A, Novin M. Marginal bone loss around platform-switched and non-platform switched implants after two years of placement: A clinical trial. J Dent Res Dent Clin Dent Prospects. 2017;11(1):26-9. .

  2. Yan Q, Xiao LQ, Su MY, Mei Y, Shi B. Soft and hard tissue changes following immediate placement or immediate restoration of single-tooth implants in the esthetic zone: A systematic review and meta-analysis. Int J Oral Maxillofac Implants. 2016;31(6):1327-40. .

  3. Mangano FG, Shibli JA, Sammons RL, Iaculli F, Piattelli A, Mangano C. Short (8-mm) locking-taper implants supporting single crowns in posterior region: A prospective clinical study with 1 to 10 years of follow-up. Clin Oral Implants Res. 2014;25(8):933-40. .

  4. Raes F, Eccellente T, Lenzi C, Ortolani M, Luongo G, Mangano C, Mangano M. Immediate functional loading of single implants: A multicenter study with 4 years of follow-up. J Dent Res Dent Clin Dent Prospects. 2018;12(1): 26-37. .

  5. Kim TH, Knezevic A, Jorgensen M, Rich S, Nowzari H. Prospective, 1-year observational study of double-threaded tapered body dental implants with immediate loading. J Prosthet Dent. 2015;114(1):46-51. .

  6. Esposito M, Grusovin MG, Maghaireh H, Worthington HV. Interventions for replacing missing teeth: Different times for loading dental implants. Cochrane Database Syst Rev. 2013(3):CD003878. .

  7. Suarez F, Chan HL, Monje A, Galindo-Moreno P, Wang HL. Effect of the timing of restoration on implant marginal bone loss: A systematic review. J Periodontol. 2013;84(2):159-69. .

  8. Pigozzo MN, Rebelo da Costa T, Sesma N, Lagana DC. Immediate versus early loading of single dental implants: A systematic review and meta-analysis. J Prosthet Dent. 2018;120(1):25-34. .

  9. Cardaropoli G, Wennstrom JL, Lekholm U. Peri-implant bone alterations in relation to inter-unit distances. A 3-year retrospective study. Clin Oral Implants Res. 2003;14(4):430-6. .

  10. Albrektsson T, Zarb G, Worthington P, Eriksson A. The long-term efficacy of currently used dental implants: A review and proposed criteria of success. Int J Oral Maxillo- fac Implants. 1986;1(1):11-25. .

  11. Da Silva JD, Kazimiroff J, Papas A, Curro FA, Thompson VP, Vena DA, Wu H, Collie D, Craig RG. Outcomes of implants and restorations placed in general dental practices: A retrospective study by the Practitioners Engaged in Applied Research and Learning (PEARL) Network. J Am Dental Assoc. 2014;145(7):704-13. .

  12. Papaspyridakos P. Implant success rates for single crowns and fixed partial dentures in general dental practices may be lower than those achieved in well-controlled university or specialty settings. J Evid Based Dent Pract. 2015;15(1):30-2. .

  13. Pessoa RS, Sousa RM, Pereira LM, Neves FD, Bezerra FJ, Jaecques SV, Sloten JV, Quirynen M, Teughels W, Spin-Neto R. Bone remodeling around implants with external hexagon and morse-taper connections: A randomized, controlled, split-mouth, clinical trial. Clin Implant Dent Relat Res. 2017;19(1):97-110. .

  14. Cvar JF, Ryge G. Reprint of criteria for the clinical evaluation of dental restorative materials. 1971. Clin Oral Investigat. 2005;9(4):215-32. .

  15. den Hartog L, Raghoebar GM, Stellingsma K, Vissink A, Meijer HJ. Immediate non-occlusal loading of single implants in the aesthetic zone: A randomized clinical trial. J Clin Periodontol. 2011;38(2):186-94. .

  16. Degidi M, Nardi D, Piattelli A. Immediate versus one-stage restoration of small-diameter implants for a single missing maxillary lateral incisor: A 3-year randomized clinical trial. J Periodontol. 2009;80(9):1393-8. .

  17. Benic GI, Mir-Mari J, Hammerle CH. Loading protocols for single-implant crowns: A systematic review and meta-analysis. Int J Oral Maxillofac Implants. 2014;29(Suppl):222-38. .

  18. Laurell L, Lundgren D. Marginal bone level changes at dental implants after 5 years in function: A meta-analysis. Clin Implant Dent Relat Res. 2011;13(1):19-28. .

  19. den Hartog L, Slater JJ, Vissink A, Meijer HJ, Raghoebar GM. Treatment outcome of immediate, early and conventional single-tooth implants in the aesthetic zone: A systematic review to survival, bone level, soft-tissue, aesthetics and patient satisfaction. J Clin Periodontol. 2008;35(12):1073-86. .

  20. Gjelvold B, Kisch J, Chrcanovic BR, Albrektsson T, Wennerberg A. Clinical and radiographic outcome following immediate loading and delayed loading of single-tooth implants: Randomized clinical trial. Clin Implant Dent Relat Res. 2017;19(3):549-58. .

  21. Calandriello R, Tomatis M. Immediate occlusal loading of single lower molars using Branemark System(R) Wide Platform TiUnite implants: A 5-year follow-up report of a prospective clinical multicenter study. Clin Implant Dent Relat Res. 2011;13(4):311-8. .

  22. Degidi M, Petrone G, Iezzi G, Piattelli A. Histologic evaluation of a human immediately loaded titanium implant with a porous anodized surface. Clin Implant Dent Relat Res. 2002;4(2):110-4. .

  23. Madani E, Smeets R, Freiwald E, Sanj MS, Jung O, Grubeanu D, Hanken H, Henningsen A. Impact of different placement depths on the crestal bone level of immediate versus delayed placed platform-switched implants. J Cranio Maxillo Facial Surg. 2018;46(7):1139-46. .

  24. Ata-Ali J, Flichy-Fernandez AJ, Ata-Ali F, Penarrocha-Diago M, Penarrocha-Diago M. Clinical, microbiologic, and host response characteristics in patients with peri-implant mucositis. Int J Oral Maxillofac Implants. 2013;28(3): 883-90. .

  25. Cannizzaro G, Torchio C, Felice P, Leone M, Esposito M. Immediate occlusal versus non-occlusal loading of single zirconia implants. A multicentre pragmatic randomised clinical trial. Eur J Oral Implantol. 2010;3(2):111-20. .

  26. Malloy KA, Wadhwani C, McAllister B, Wang M, Katancik JA. Accuracy and reproducibility of radiographic images for assessing crestal bone height of implants using the precision implant X-ray locator (PIXRL) device. Int J Oral Maxillofac Implants. 2017;32(4):830-6. .

  27. Needleman I, Chin S, O'Brien T, Petrie A, Donos N. Systematic review of outcome measurements and reference group(s) to evaluate and compare implant success and failure. J Clin Periodontol. 2012;39(Suppl 12):122-32. .

  28. Bayne SC, Schmalz G. Reprinting the classic article on USPHS evaluation methods for measuring the clinical research performance of restorative materials. Clin Oral Investigat. 2005;9(4):209-14. .

Prochains articles

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka