Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
Heat Transfer Research
Facteur d'impact: 0.404 Facteur d'impact sur 5 ans: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimer: 1064-2285
ISSN En ligne: 2162-6561

Volumes:
Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2018020931
pages 1489-1505

CuO/WATER NANOFLUID FLOW OVER MICROSCALE BACKWARD-FACING STEP AND ANALYSIS OF HEAT TRANSFER PERFORMANCE

Recep Ekiciler
Department of Mechanical Engineering, Gazi University, Ankara, Turkey
Kamil Arslan
Department of Mechanical Engineering, Karabük University, Karabük, Turkey

RÉSUMÉ

Three-dimensional numerical simulation of steady-state laminar forced convection flow of a CuO/water nanofluid and heat transfer in a duct having a microscale backward-facing step (MBFS) are presented in this study. The study was conducted for determining the effects of nanoparticle volume fraction on the flow and heat transfer characteristics. The Reynolds number ranged from 100 to 1000. The step height and inlet height of the duct were 600 μm and 400 μm, respectively. The duct expansion ratio was 2.5. The downstream wall was subjected to a constant and uniform heat flux, whereas the other walls were insulated. The nanoparticle volume fraction varied from 1.0% to 4.0%. The Nusselt number and Darcy friction factor were obtained for each nanoparticle volume fraction. Plots of velocity streamlines were analyzed. It was found from the results of numerical simulation that the Nusselt number increases with increasing nanoparticle volume fraction and Reynolds number. The nanoparticle volume fraction does not exert any substantial effect on the Darcy friction factor and the length of the recirculation zone. Moreover, the performance evaluation criterion (PEC) was analyzed for nanoparticle volume fractions of 1.0%, 2.0%, 3.0%, and 4.0% of CuO. It was obtained that the volume fractions of 4.0% has the highest PEC in terms of heat transfer. It was obtained that while heat transfer for nanoparticle volume fraction of 30% and 4.0% the friction factor is superior for nanoparticle volume fraction of 1.0% and 2.0% due to the PEC number.


Articles with similar content:

NUMERICAL INVESTIGATION OF A COPPER—WATER NANOFLUID FLOWING IN A PARALLEL PLATE CHANNEL
Heat Transfer Research, Vol.50, 2019, issue 7
Saeb Ragani, Arian Bahrami
THE EFFECT OF CHAMFER LENGTH ON THERMAL AND HYDRAULIC PERFORMANCE BY USING Al2O3-WATER NANOFLUID THROUGH A SQUARE CROSS-SECTIONAL DUCT
Heat Transfer Research, Vol.50, 2019, issue 12
Orhan Keklikcioglu, Veysel Ozceyhan, Toygun Dagdevir
THERMAL PERFROMANCE OF COOLING CHANNELS WITH RIBARRAYS DETACHED FROM ONE WALL
Second Thermal and Fluids Engineering Conference, Vol.24, 2017, issue
Sebastian Ruck, Benedikt Kaiser, Frederik Arbeiter
MIXED-CONVECTION NANOFLUID FLOW THROUGH A GROOVED CHANNEL WITH INTERNAL HEAT GENERATING SOLID CYLINDERS IN THE PRESENCE OF AN APPLIED MAGNETIC FIELD
Heat Transfer Research, Vol.50, 2019, issue 3
Davood Semiromi Toghraie, Mohammad Sadegh Dehghani, Babak Mehmandoust
A NUMERICAL STUDY OF NANOFLUID FORCED CONVECTION IN A POROUS CHANNEL WITH DISCRETE HEAT SOURCES
Journal of Porous Media, Vol.17, 2014, issue 6
Payam Rahim Mashaei, Seyed Mostafa Hosseinalipour