Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
Heat Transfer Research
Facteur d'impact: 0.404 Facteur d'impact sur 5 ans: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimer: 1064-2285
ISSN En ligne: 2162-6561

Volumes:
Volume 51, 2020 Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2014006774
pages 293-309

EXPERIMENTAL INVESTIGATION OF A REHEATING TWO-STAGE ADSORPTION CHILLER APPLYING FIXED CHILLED WATER OUTLET CONDITIONS

I Gusti Agung Bagus Wirajati
Graduate School of Bio-Applications and Systems Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei-shi, 184-8588, Tokyo, Japan; Bali State Polytechnic, Bukit Jimbaran, Kuta Selatan, Bali 80364
Atsushi Akisawa
Graduate School of Bio-Applications and Systems Engineering (BASE), Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei-shi, Tokyo 184-8588, Japan
Yuki Ueda
Graduate School of Bio-Applications and Systems Engineering (BASE), Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei-shi, Tokyo 184-8588, Japan
Takahiko Miyazaki
Faculty of Engineering Sciences, Kyushu University, 6-1 Kasuga-koen, Kasuga-shi, Fukuoka, 816-8580, Japan

RÉSUMÉ

The adsorption refrigeration chiller is environmentally friendly because of the use of a natural refrigerant and the use of a low-grade thermal energy as the driving energy source. In this paper, an experimental investigation of a reheating two-stage adsorption chiller was conducted, and the working principle of the cycle was also introduced. The coefficient of performance and the cooling capacity were calculated to analyze the performance of the chiller. Our objective was to identify the effect of the temperature of the heat source and the effect of cycle time on the performance if the chilled water outlet temperature is fixed at 9° during the experiment. Experimental results showed that the performance of the chiller improved with increasing heat source temperature and that a total cycle time between 2000 to 2500 s yields better performance for the chiller.


Articles with similar content:

NON-REGENERATIVE MULTI-STAGE AND REGENERATIVE MULTI-BED ADSORPTION CYCLES FOR LOW-TEMPERATURE WASTE HEAT RECOVERY
Proceedings of Symposium on Energy Engineering in the 21st Century (SEE2000) Volume I-IV, Vol.0, 2000, issue
Kim Choon Ng, Bidyut Baran Saha, Takao Kashiwagi, Hui Tong Chua, Atsushi Akisawa
EFFECT OF VOLUME OF EVAPORATOR AND BED HEAT EXCHANGER ON PERFORMANCE OF ADSORPTION CHILLER
3rd Thermal and Fluids Engineering Conference (TFEC), Vol.26, 2018, issue
Gamze Gediz Ilis, Hasan Demir
SIMULATION OF HEAT AND MASS TRANSFER PERFORMANCE WITH CONSOLIDATED COMPOSITE ACTIVATED CARBON
Heat Transfer Research, Vol.46, 2015, issue 2
Liwei Wang, Z. Q. Jin, Morgane Fleurance, L. Jiang, R Z Wang, Yanjie Zhao
THERMAL PERFORMANCE OF GROUND SOURCE HEAT PUMPS THAT USE DIRECT EXPANSION METHOD USING FOUNDATION PILE
International Heat Transfer Conference 16, Vol.20, 2018, issue
Osamu Yoda, Tetsuaki Takeda, Shuhei Ishiguro, Hiroji Okubo
STUDY ON ACF/ETHANOL BASED TWO STAGE ADSORPTION COOLING CYCLE
International Heat Transfer Conference 13, Vol.0, 2006, issue
Kim Choon Ng, Bidyut Baran Saha, Anutosh Chakraborty, Shigeru Koyama, Ibrahim I. El-Sharkawy