Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
Heat Transfer Research
Facteur d'impact: 0.404 Facteur d'impact sur 5 ans: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimer: 1064-2285
ISSN En ligne: 2162-6561

Volumes:
Volume 51, 2020 Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2014006867
pages 271-291

INVESTIGATION OF THE ABSORPTION−COMPRESSION HYBRID REFRIGERATION APPLIED TO THE COACH AIR CONDITIONING

Jianbo Li
Key Laboratory of Ocean Energy Utilization and Energy Conservation of Ministry of Education, School of Energy and Power, Dalian University of Technology, Dalian, China
Shiming Xu
Dalian University of Technology, 2 Ling Gong Rd. Gan Jingzi District, Dalian 116024, China
Shaokang Kong
Key Laboratory of Ocean Energy Utilization and Energy Conservation of Ministry of Education, School of Energy and Power, Dalian University of Technology, Dalian, China

RÉSUMÉ

The waste heat characteristics of the exhaust gases from the coach engine were analyzed at different coach running speeds and different gears. Based on the waste heat load, the cycle thermal calculation results and the given operating conditions, the structural parameters of the main devices in the absorption−compression hybrid refrigeration cycles (ACHRC) were determined. The conditions of the temperatures of cooling air, condensation, and evaporation are 35°C, 55°C, and 3°C, respectively, and the coach air-conditioning load is 30 kW. The performance of the ACHRC was investigated by coupling the heat transfer equations for the devices in the ACHRC and the cycle thermal calculation equations. The results indicate that the absorption refrigeration subcycle (ARSC) driven by the gases can completely meet the coach cooling requirement when the coach running speed reaches 105 km·h−1. The cooling load is fully supplied by the compression refrigeration subcycle (CRSC) powered by the engine output when the coach running speed is lower than 40 km·h−1.


Articles with similar content:

COMPARISON AND ANALYSIS ON THE PERFORMANCE OF R404A DIRECT CONTACT CONDENSATION REFRIGERATION CYCLE FOR LOW TEMPERATURE
International Heat Transfer Conference 16, Vol.23, 2018, issue
Jinghong Ning , Qiang Dong , Shengchun Liu
TECHNOECONOMIC STUDY OF WASTE HEAT RECOVERY STRATEGIES FOR NATURAL GAS COMBINED CYCLE POWER PLANTS
3rd Thermal and Fluids Engineering Conference (TFEC), Vol.32, 2018, issue
Todd M. Bandhauer, Achyut Paudel
EXERGY ANALYSIS OF A PUMP-DRIVEN LOOP HEAT PIPE FOR FREE COOLING IN DATA CENTERS
International Heat Transfer Conference 16, Vol.23, 2018, issue
Feng Zhou, Guoyuan Ma, Cuicui Li , Wanpeng Zhu, Xianghui Yan , Fuping Li
PERFORMANCE MODEL OF A WASTE HEAT DRIVEN TURBO-COMPRESSION CHILLER
Second Thermal and Fluids Engineering Conference, Vol.14, 2017, issue
Jeff Noall, Shane D. Garland, Todd M. Bandhauer
NUMERICAL ANALYSIS OF A THERMALLY DRIVEN THERMOACOUSTIC HEAT PUMP FOR LOW-GRADE HEAT RECOVERY
Computational Thermal Sciences: An International Journal, Vol.6, 2014, issue 4
Ali Al-Kayiem, Zhibin Yu