Volume 22, 2019 Volume 21, 2018 Volume 20, 2017 Volume 19, 2016 Volume 18, 2015 Volume 17, 2014 Volume 16, 2013 Volume 15, 2012 Volume 14, 2011 Volume 13, 2010 Volume 12, 2009 Volume 11, 2008 Volume 10, 2007 Volume 9, 2006 Volume 8, 2005 Volume 7, 2004 Volume 6, 2003 Volume 5, 2002 Volume 4, 2001 Volume 3, 2000 Volume 2, 1999 Volume 1, 1998

Journal of Porous Media

DOI: 10.1615/JPorMedia.v15.i2.20
pages 113-122

THE ROLE OF POROUS MEDIA IN MODELING FLUID FLOW WITHIN HOLLOW FIBER MEMBRANES OF THE TOTAL ARTIFICIAL LUNG

Khalil Khanafer
Mechanical Engineering Department, Australian College of Kuwait, Safat 13015, Kuwait
Keith Cook
Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109, USA;Department of Surgery, University of Michigan, Ann Arbor, Michigan 48109, USA
Alia Marafie
Mechanical Engineering Department, Kuwait University, Al-Safat, Kuwait

RÉSUMÉ

A numerical study was conducted to analyze fluid flow within hollow fiber membranes of the artificial lungs. The hollow fiber bundle was approximated using a porous media model. In addition, the transport equations were solved using the finite-element formulation based on the Galerkin method of weighted residuals. Comparisons with previously published work on the basis of special cases were performed and found to be in excellent agreement. A Newtonian viscous fluid model for the blood was used. Different flow models for porous media, such as the Brinkman-extended Darcy model, Darcy’s law model, and the generalized flow model, were considered. Results were obtained in terms of streamlines, velocity vectors, and pressure distribution for various Reynolds numbers and Darcy numbers. The results from this investigation showed that the pressure drop across the artificial lung device increased with an increase in the Reynolds number. In addition, the pressure drop was found to increase significantly for small Darcy numbers.


Articles with similar content:

MODELING OF FLOW THROUGH A REACTIVE POROUS PLUG AS RELATED TO BIOLOGICAL APPLICATIONS
Journal of Porous Media, Vol.15, 2012, issue 9
Alia Marafie
NATURAL CONVECTION IN A TRAPEZOIDAL ENCLOSURE FILLED WITH A NON-DARCIAN POROUS MEDIUM
Journal of Porous Media, Vol.14, 2011, issue 6
Bader Alshriaan Al-Azmi
COMPUTATIONAL MODELING OF FLOW AND SPECIES DISTRIBUTION IN A MEMBRANELESS FUEL CELL WITH POROUS ELECTRODES
Journal of Porous Media, Vol.20, 2017, issue 8
Yusuf I. Ali, Fadhel A. Azeez, Khalil Khanafer
Numerical Modeling of Turbulent Flow in Porous Media Using a Spatially Periodic Array
Journal of Porous Media, Vol.1, 1998, issue 1
S. Yamashita, Fujio Kuwahara, Akira Nakayama, Y. Kameyama
MIXED CONVECTION FLOW AND HEAT TRANSFER IN A VENTED ENCLOSURE FILLED PARTIALLY WITH A POROUS MEDIUM
Journal of Porous Media, Vol.16, 2013, issue 10
Bader Alshriaan