Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
Critical Reviews™ in Biomedical Engineering
SJR: 0.26 SNIP: 0.375 CiteScore™: 1.4

ISSN Imprimer: 0278-940X
ISSN En ligne: 1943-619X

Volumes:
Volume 48, 2020 Volume 47, 2019 Volume 46, 2018 Volume 45, 2017 Volume 44, 2016 Volume 43, 2015 Volume 42, 2014 Volume 41, 2013 Volume 40, 2012 Volume 39, 2011 Volume 38, 2010 Volume 37, 2009 Volume 36, 2008 Volume 35, 2007 Volume 34, 2006 Volume 33, 2005 Volume 32, 2004 Volume 31, 2003 Volume 30, 2002 Volume 29, 2001 Volume 28, 2000 Volume 27, 1999 Volume 26, 1998 Volume 25, 1997 Volume 24, 1996 Volume 23, 1995

Critical Reviews™ in Biomedical Engineering

DOI: 10.1615/CritRevBiomedEng.v28.i12.220
pages 129-134

Performance of Enlarged Blood Pump Models With Five Different Impellers

Leok Poh Chua
School of Mechanical and Production Engineering, Nanyang Technological University, Nanyang Avenue, Singapore 639798
Simon C.M. Yu
Nanyang Technological University, Singapore and Singapore Institute of Technology, Singapore. The Hong Kong Polytechnic University, Hong Kong
H. L Leo
School of Mechanical and Production Engineering, Nanyang Technological University, Nanyang Avenue, Singapore 639798

RÉSUMÉ

In earlier studies, a 5:1 enlarged pump model of the Kyoto-NTN Magnetically Suspended Centrifugal Blood Pump had been constructed and the flow characteristics investigated. Although the results obtained were satisfactory, the medium used was air. A 5:1 enlarged pump model using water as the medium thus was designed and constructed. Five different impeller blade profile designs were used in the present study. By varying (1) the blade profile design: forward, radial, and backward, (2) the number of blades used, and (3) the rotating speed, the flow characteristics of the pump were investigated. It was found that the impeller with the higher number of blades, used in the forward and straight blade profiles, have the best performance.


Articles with similar content:

Measurements of Enlarged Blood Pump Models Using Laser Doppler Anemometer
Critical Reviews™ in Biomedical Engineering, Vol.28, 2000, issue 1&2
H. L Leo, Simon C.M. Yu, Leok Poh Chua
PERFORMANCE OPTIMIZATION OF CENTRIFUGAL PUMP HANDLING VISCOUS OIL BY MODIFICATION OF IMPELLER GEOMETRY
International Journal of Fluid Mechanics Research, Vol.44, 2017, issue 5
Mojtaba Tahani , Amir F. Najafi, Majid Najafpour, Sepehr Govara
DESIGN AND ANALYSIS OF A DUCTED CONTRA-ROTATING AXIAL FLOW FAN
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2014, issue
Ali Mohammadi, Masoud Boroomand, Hamzeh Eshraghi
Blade and Vane Leading Edge Fillet on Endwall Cooling in Linear Turbine Cascades
International Heat Transfer Conference 15, Vol.20, 2014, issue
Sumanta Acharya, Gazi I. Mahmood
NUMERICAL ANALYSIS OF THERMAL PERFORMANCE OF A SWIRL COOLING TUBE WITH DIMPLES AT THE WALL
International Heat Transfer Conference 16, Vol.10, 2018, issue
Bernhard Weigand, Tian Xia, Yuyang Liu, Yu Rao