Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
Critical Reviews™ in Biomedical Engineering
SJR: 0.207 SNIP: 0.376 CiteScore™: 0.79

ISSN Imprimer: 0278-940X
ISSN En ligne: 1943-619X

Volumes:
Volume 47, 2019 Volume 46, 2018 Volume 45, 2017 Volume 44, 2016 Volume 43, 2015 Volume 42, 2014 Volume 41, 2013 Volume 40, 2012 Volume 39, 2011 Volume 38, 2010 Volume 37, 2009 Volume 36, 2008 Volume 35, 2007 Volume 34, 2006 Volume 33, 2005 Volume 32, 2004 Volume 31, 2003 Volume 30, 2002 Volume 29, 2001 Volume 28, 2000 Volume 27, 1999 Volume 26, 1998 Volume 25, 1997 Volume 24, 1996 Volume 23, 1995

Critical Reviews™ in Biomedical Engineering

DOI: 10.1615/CritRevBiomedEng.v28.i34.100
pages 405-410

A 3-D FEM Analysis of Single and Multiple Screw-Root Dental Implant Fixed in a Mandible

Amit Roychowdhury
Department of Aerospace Engineering and Applied Mechanics, Indian Institute of Engineering Science and Technology, Shibpur, India
S. Pal
School of BioScience and Engineering, Jadavpur University, Calcutta-700 032

RÉSUMÉ

Replacement of single tooth using a threaded titanium screw root coated with hydroxyapatite (HA) for faster bone apposition to implant site is common. Uncoated pure titanium is also used for osseointegration. Usually bone fixation of implant takes four to six months in either case. Quite often, a good number of teeth in a mandible or maxilla are replaced. Usually it is often said that bones appear to be well designed from the point of view of structural engineering. The "maximum-minimum law" claimed by Roux is a rational concept that states that bone provides maximum strength with a minimum of construction material. According to this proposition, stress distribution in bone will be almost uniform under a set of loading conditions. This was found to be true in the case of normal human mandibular bone as examined by some Japanese scientists. The present authors are interested in examining the stress distribution during multiple single tooth replacements using 3D-FEM technique to ascertain how the stress pattern changes with such implantation of three screws in a row in the human mandible, as we are in the process of clinical trial of hydroxyapatite coated and uncoated titanium implant. This will be of considerable interest to the dental surgeons, who prompted us to address this problem.
Our results depicted the mean values of various stress in cortical and cancellous bone while applying the maximum masticatory load of 50 N in each teeth. The generated stress level is within the safe range of stress for bones. However, such screws cannot be applied to osteoporotic or other diseased mandible where bone strength may be quite low.


Articles with similar content:

Proposed Frequencies of a Vibrator Used for Implant Retrieval at the Time of Hip Joint Revision Surgery
Journal of Long-Term Effects of Medical Implants, Vol.19, 2009, issue 2
Vijay J. Rasquinha, Westley T. Hayes, Amit Roychowdhury
Anterior Cruciate Ligament Reconstruction with the Leeds-Keio Artificial Ligament
Journal of Long-Term Effects of Medical Implants, Vol.10, 2000, issue 4
Kyosuke Fujikawa, Yoshihiro Sasazaki, Hideo Matsumoto, Tatsuo Kobayashi, Bahaa B. Seedhom
Biomechanical Analysis of CT Scan-based Hip Prosthesis With an Optimal Hip Ball by Using Finite Element Analysis
Journal of Long-Term Effects of Medical Implants, Vol.19, 2009, issue 1
D. Sengupta, U.B. Ghosh, Amit Roychowdhury, S. Pal
High Insertion Torque and Peri-Implant Bone Loss: Is There a Relationship?
Journal of Long-Term Effects of Medical Implants, Vol.25, 2015, issue 3
Mohsen Bidgoli, Javad Faradmal, Sepideh Soheilifar, Sara Soheilifar
Evidence That In Vivo Wear Damage Alters Kinematics and Contact Stresses in a Total Knee Replacement
Journal of Long-Term Effects of Medical Implants, Vol.20, 2010, issue 1
David W. Holdsworth, John L. Williams, Matthew G Teeter, David A. Knox, William M. Mihalko