Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
Journal of Enhanced Heat Transfer
Facteur d'impact: 0.562 Facteur d'impact sur 5 ans: 0.605 SJR: 0.211 SNIP: 0.361 CiteScore™: 0.33

ISSN Imprimer: 1065-5131
ISSN En ligne: 1026-5511

Volumes:
Volume 26, 2019 Volume 25, 2018 Volume 24, 2017 Volume 23, 2016 Volume 22, 2015 Volume 21, 2014 Volume 20, 2013 Volume 19, 2012 Volume 18, 2011 Volume 17, 2010 Volume 16, 2009 Volume 15, 2008 Volume 14, 2007 Volume 13, 2006 Volume 12, 2005 Volume 11, 2004 Volume 10, 2003 Volume 9, 2002 Volume 8, 2001 Volume 7, 2000 Volume 6, 1999 Volume 5, 1998 Volume 4, 1997 Volume 3, 1996 Volume 2, 1995 Volume 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.2013006564
pages 43-58

AIRSIDE PERFORMANCE OF FIN-AND-TUBE HEAT EXCHANGERS HAVING SINE WAVE OR SINE WAVE-SLIT FINS

Nae-Hyun Kim
Department of Mechanical Engineering, Incheon National University, 12-1 Songdo-Dong, Yeonsu-Gu Inchon, 22012, Korea
Baek Youn
Air Conditioner and Refrigerator Division, Samsung Electronics Co., Suwon, Korea

RÉSUMÉ

The heat transfer and friction characteristics of heat exchangers having sine wave or sine wave-slit fins were experimentally investigated. Thirty-eight samples having different waffle heights (1.5 and 2.0 mm), fin pitches (1.3 to 1.7 mm), and tube rows (one to three) were tested. Results show that the sine wave-slit geometry provided 20% higher heat transfer coefficients and 44% higher friction factors than the sine wave geometry. The j/f ratios of the sine wave geometry, however, were higher than those of the sine wave-slit geometry. Within the present geometric variations, the effect of waffle height on the heat transfer coefficient was not prominent. The effect of fin pitch on j and f factor was also negligible for sine wave fin. For sine wave-slit fin, however, both j and f factors increased as fin pitch decreased. New correlations were developed based on the present data.


Articles with similar content:

AN EXPERIMENTAL INVESTIGATION OF THE AIR-SIDE PERFORMANCE OF FIN-AND-TUBE HEAT EXCHANGERS HAVING SLIT FINS
Journal of Enhanced Heat Transfer, Vol.22, 2015, issue 1
Honggi Cho, Nae-Hyun Kim
Some Aspects of Plate Fin-and-Tube Heat Exchangers: With and Without Louvers
Journal of Enhanced Heat Transfer, Vol.6, 1999, issue 5
Chang-Tsair Chang, Yu-Juei Chang, Chi-Juan Lee, Chi-Chuan Wang
EXPERIMENTAL INVESTIGATION OF HEAT TRANSFER, FRICTION FACTOR, AND OPTIMAL FIN GEOMETRIES FOR THE INTERNALLY MICROFIN TUBES IN THE TRANSITION AND TURBULENT REGIONS
Journal of Enhanced Heat Transfer, Vol.19, 2012, issue 5
Sik Chung Tam, Afshin J. Ghajar, Hou Kuan Tam, Tong Zhang, Lap Mou Tam
HEAT TRANSFER AND FRICTION CHARACTERISTICS OF FIN-AND-TUBE HEAT EXCHANGERS
Proceedings of Symposium on Energy Engineering in the 21st Century (SEE2000) Volume I-IV, Vol.0, 2000, issue
Wei-Mon Yan, Pay-Jen Sheen
BRAZED ALUMINUM HEAT EXCHANGERS AND THEIR AIR SIDE PERFORMANCE
Journal of Enhanced Heat Transfer, Vol.24, 2017, issue 1-6
Yu-Juei Chang, Chi-Chuan Wang