Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
Journal of Enhanced Heat Transfer
Facteur d'impact: 0.562 Facteur d'impact sur 5 ans: 0.605 SJR: 0.175 SNIP: 0.361 CiteScore™: 0.33

ISSN Imprimer: 1065-5131
ISSN En ligne: 1026-5511

Volumes:
Volume 27, 2020 Volume 26, 2019 Volume 25, 2018 Volume 24, 2017 Volume 23, 2016 Volume 22, 2015 Volume 21, 2014 Volume 20, 2013 Volume 19, 2012 Volume 18, 2011 Volume 17, 2010 Volume 16, 2009 Volume 15, 2008 Volume 14, 2007 Volume 13, 2006 Volume 12, 2005 Volume 11, 2004 Volume 10, 2003 Volume 9, 2002 Volume 8, 2001 Volume 7, 2000 Volume 6, 1999 Volume 5, 1998 Volume 4, 1997 Volume 3, 1996 Volume 2, 1995 Volume 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.2017015985
pages 175-195

ANALYSIS OF THE IMPACT OF U-SHAPED STRUCTURE FOR HEADS OF LOOP THERMOSYPHON SOLAR WATER HEATER ON THERMAL STORAGE EFFICIENCY

Chien Huang
Engineering & System Science Department, National Tsing-Hua University 101, Sec. 2, Kuang Fu Rd., Hsinchu, Taiwan
Wei-Keng Lin
Department of Engineering and System Science, National Tsing-Hua University, Hsinchu City, Taiwan
Sung-Ren Wang
Engineering & System Science Department, National Tsing-Hua University 101, Sec. 2, Kuang Fu Rd., Hsinchu, Taiwan

RÉSUMÉ

Loop thermosyphons are high-efficiency two-phase heat transfer devices capable of transporting thermal energy over long distances. In this paper, we present experiment results for three loop thermosyphon designs for use in solar water heaters: non-U-symmetric loop (asymmetric type), top-U-symmetric loop (symmetric vapor heads type), and both-U-symmetric loop (symmetric vapor and liquid heads type). Experiments were conducted to investigate thermal storage efficiency and temperature distribution under various heat loads and fill ratios. Our results demonstrate the importance of fill ratio and shape of the structure on thermal storage efficiency. The highest thermal storage efficiency values obtained in this study were as follows: non-U-symmetric loop (64.7%), top-U-symmetric loop, (79.8%), and both-U-symmetric loop thermosyphon (73.8%). Our simulation of daily operations revealed that a top-U-symmetric loop provides the best overall performance.


Articles with similar content:

EXPERIMENTAL INVESTIGATION OF LOOP HEAT PIPE APPLIED IN A RAILING-TYPE COLLECTOR SOLAR WATER HEATER
Heat Transfer Research, Vol.48, 2017, issue 13
Wei-Keng Lin, Yu-Lin Chuang, Chien Huang
ENERGY AND EXERGY EFFICIENCY OF A HEAT STORAGE UNIT FOR BUILDING HEATING
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2009, issue
Mejdi Hazami, Meriem Lazaar, Sami Kooli, Ali Belghith, Abdelhamid Farhat
EXPERIMENTAL INVESTIGATION OF NOVEL DESIGN OF SOLAR COOKER WITH DUAL THERMAL STORAGE UNIT BASED ON PARABOLIC DISH-TYPE COLLECTOR
International Journal of Energy for a Clean Environment, Vol.14, 2013, issue 4
Avadhesh Yadav, Vikrant Yadav
Numerical Analysis and Optimization of a Complex Geometry, High Temperature Heat Pipe
First Thermal and Fluids Engineering Summer Conference, Vol.4, 2015, issue
Mahboobe Mahdavi, Songgang Qiu
DESIGN, CONSTRUCTION, AND TESTING OF A CYLINDRICAL SOLAR WATER HEATER
International Journal of Energy for a Clean Environment, Vol.10, 2009, issue 1-4
M. C. Njoku, E. E. Anyanwu, Nnamdi V. Ogueke