Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
Journal of Enhanced Heat Transfer
Facteur d'impact: 0.562 Facteur d'impact sur 5 ans: 0.605 SJR: 0.175 SNIP: 0.361 CiteScore™: 0.33

ISSN Imprimer: 1065-5131
ISSN En ligne: 1026-5511

Volumes:
Volume 27, 2020 Volume 26, 2019 Volume 25, 2018 Volume 24, 2017 Volume 23, 2016 Volume 22, 2015 Volume 21, 2014 Volume 20, 2013 Volume 19, 2012 Volume 18, 2011 Volume 17, 2010 Volume 16, 2009 Volume 15, 2008 Volume 14, 2007 Volume 13, 2006 Volume 12, 2005 Volume 11, 2004 Volume 10, 2003 Volume 9, 2002 Volume 8, 2001 Volume 7, 2000 Volume 6, 1999 Volume 5, 1998 Volume 4, 1997 Volume 3, 1996 Volume 2, 1995 Volume 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.2017020823
pages 241-262

EFFECTS ON ENDWALL HEAT TRANSFER BY A WINGLET VORTEX GENERATOR PAIR MOUNTED UPSTREAM OF A CYLINDER

Safeer Hussain
Energy Sciences Heat Transfer Division, Lund University, Box 118, SE-22100 Lund, Sweden
Jian Liu
Energy Sciences Heat Transfer Division, Lund University, Box 118, SE-22100 Lund, Sweden
Lei Wang
Division of Heat Transfer, Department of Energy Sciences, Lund University, Box 118, Lund, SE-2 2 100, Sweden
Bengt Sunden
Division of Heat Transfer, Department of Energy Sciences, Lund University, P.O. Box 118, SE-22100, Lund, Sweden

RÉSUMÉ

The present study was conducted to investigate heat transfer enhancement from the endwall of a protruding circular cylinder by addition of a winglet vortex generator pair. A steady-state liquid crystal thermography technique was employed. The vortex generator pair is installed upstream of a cylinder placed either in counter flow inward or counter flow outward orientation. The vortex generator installed in the counter flow inward orientation presented the best heat transfer. The effects of the vortex generator attack angle on the junction wall heat transfer are also investigated and the 45° yaw angle with respect to the streamwise direction provided higher thermal performance. The position of the vortex generator with respect to the cylindrical obstacle is swapped in the streamwise and spanwise directions to find out the appropriate location of the vortex generator regarding enhancement of endwall heat transfer. The results indicated that the effect of the vortex generator in enhancing the endwall heat transfer is prominent in the spanwise direction rather than in the streamwise direction. Up to 25% heat transfer enhancement has been found with a pressure drop penalty of 4.8%, thus giving high thermal performance.


Articles with similar content:

EXPERIMENTAL INVESTIGATION OF HEAT TRANSFER ENHANCEMENT ON THE ENDWALL AROUND AN OBSTACLE EMBEDDED WITH A VORTEX GENERATOR PAIR
International Heat Transfer Conference 16, Vol.14, 2018, issue
Lei Wang, Bengt Sunden, Safeer Hussain, Jian Liu
MEASUREMENT OF HEAT TRANSFER ON TURBINE BLADE ENDWALL WITH UPSTREAM WAKES AT DIFFERENT RELATIVE POSITIONS
International Heat Transfer Conference 16, Vol.10, 2018, issue
Sehjin Park, Ho-Seong Sohn, Osamu Ueda, Yang Seok Han, Hyung-Hee Cho
INTERACTIONS OF COMBUSTOR WALL AND FILM COOLING ON ENDWALL FOR A FIRST-STAGE VANE
Second Thermal and Fluids Engineering Conference, Vol.4, 2017, issue
Zhao Liu, Xing Yang, Zhenping Feng, Zhansheng Liu
LIQUID CRYSTAL VISUALIZATIONS AND MEASUREMENTS OF HEAT TRANSFER IN A SQUARE DUCT WITH DIFFERENT PITCHES OF VORTEX GENERATOR ARRAYS
Journal of Flow Visualization and Image Processing, Vol.5, 1998, issue 4
Tzi-Wei Tsai, Chung-Chu Chen, Tong-Miin Liou
NUMERICAL STUDY ON FLOW AND HEAT TRANSFER IN A RECTANGULAR CHANNEL WITH 45 DEG RIB TURBULATORS AND BLEED HOLES
Journal of Enhanced Heat Transfer, Vol.19, 2012, issue 5
Ya Jun Song, Zhong Yang Shen, Yong Hui Xie, Di Zhang