Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
Journal of Enhanced Heat Transfer
Facteur d'impact: 0.562 Facteur d'impact sur 5 ans: 0.605 SJR: 0.211 SNIP: 0.361 CiteScore™: 0.33

ISSN Imprimer: 1065-5131
ISSN En ligne: 1026-5511

Volumes:
Volume 26, 2019 Volume 25, 2018 Volume 24, 2017 Volume 23, 2016 Volume 22, 2015 Volume 21, 2014 Volume 20, 2013 Volume 19, 2012 Volume 18, 2011 Volume 17, 2010 Volume 16, 2009 Volume 15, 2008 Volume 14, 2007 Volume 13, 2006 Volume 12, 2005 Volume 11, 2004 Volume 10, 2003 Volume 9, 2002 Volume 8, 2001 Volume 7, 2000 Volume 6, 1999 Volume 5, 1998 Volume 4, 1997 Volume 3, 1996 Volume 2, 1995 Volume 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.2011002711
pages 1-11

PERFORMANCE CHARACTERISTICS OF DEEP CORRUGATED TUBES WITH TWISTED-TAPE INSERTS

Ventsislav D. Zimparov
Gabrovo Technical University, 4 Hadji Dimitar Strasse, 5300 Gabrovo, Bulgaria
Valentin Metodiev Petkov
Gabrovo Technical University, 4, Hadji Dimitar, Str. 5300 Gabrovo, Bulgaria
Arthur E. Bergles
Department of Mechanical, Aerospace, and Nuclear Engineering, Rensselaer Polytechnic Institute, Troy, New York; University of Maryland, College Park, Maryland; Massachusetts Institute of Technology, Cambridge, Massachusetts, USA

RÉSUMÉ

Recent investigation of the performance characteristics of some passive compound heat transfer enhancement techniques revealed that the combination of corrugated tubes with twisted-tape inserts seems to be a very attractive enhancement technique for single-phase turbulent flow. This holds in the range of height-to-diameter ratios e/Di > 0.04 and small relative pitches of the twisted tape, H/Di. This paper presents the latest results of an experimental investigation of the friction factors and heat transfer coefficients (inside with water as working fluid and outside with condensing steam) of eight single-start, spirally corrugated tubes with geometrical parameters: 0.053 < e/Di < 0.089 and ridge pitch-to-height ratio 6.8 < p/e < 11.0 combined with twisted tapes with H/Di = 4.7, 5.7, and 7.6, in the range of Reynolds number, 3.5 × 103 < Re < 5.0 × 104. The increase of outside heat transfer coefficient E0 is presented as a function of geometrical parameters of the depth of the corrugated tube through the Weber number, We, and the relative pitch of the twisted tape H/Di. The effect of Reynolds number on E0 is discussed.


Articles with similar content:

Compound heat transfer enhancement by a combination of spirally corrugated tubes with a twisted tape
International Heat Transfer Conference 12, Vol.47, 2002, issue
Ventsislav D. Zimparov, Valentin Metodiev Petkov
ENHANCEMENT OF HEAT TRANSFER BY A COMBINATION OF A SINGLE START SPIRALLY CORRUGATED TUBES WITH A TWISTED TAPE
ICHMT DIGITAL LIBRARY ONLINE, Vol.1, 2000, issue
Ventsislav D. Zimparov
Experimental Study of Heat Transfer and Friction in Annular Ducts with a Heated Tube Having a Spirally Wound Helical Spring
Journal of Enhanced Heat Transfer, Vol.17, 2010, issue 1
B. K. Maheshwari, Shailesh K. Patel, Rajendra Karwa
Performance Evaluation of Deep Spirally Corrugated Tubes for Shell-and-Tube Heat Exchangers
Journal of Enhanced Heat Transfer, Vol.11, 2004, issue 4
Plamen J. Penchev, Ventsislav D. Zimparov
Turbulent Heat Transfer Enhancement and Surface Heating Effect in Square Channels with Wavy, and Twisted Tape Inserts with Interrupted Ribs
Journal of Enhanced Heat Transfer, Vol.7, 2000, issue 1
Y. M. Zhang, Je-Chin Han, G. M. Azad, Ching-Pang Lee