Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
Journal of Enhanced Heat Transfer
Facteur d'impact: 0.562 Facteur d'impact sur 5 ans: 0.605 SJR: 0.211 SNIP: 0.361 CiteScore™: 0.33

ISSN Imprimer: 1065-5131
ISSN En ligne: 1026-5511

Volumes:
Volume 26, 2019 Volume 25, 2018 Volume 24, 2017 Volume 23, 2016 Volume 22, 2015 Volume 21, 2014 Volume 20, 2013 Volume 19, 2012 Volume 18, 2011 Volume 17, 2010 Volume 16, 2009 Volume 15, 2008 Volume 14, 2007 Volume 13, 2006 Volume 12, 2005 Volume 11, 2004 Volume 10, 2003 Volume 9, 2002 Volume 8, 2001 Volume 7, 2000 Volume 6, 1999 Volume 5, 1998 Volume 4, 1997 Volume 3, 1996 Volume 2, 1995 Volume 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.v6.i5.30
pages 357-368

Some Aspects of Plate Fin-and-Tube Heat Exchangers: With and Without Louvers

Chi-Chuan Wang
Department of Mechanical Engineering Chiao Tung University, Hsinchu 300, Chinese Taipei
Chi-Juan Lee
Department of Mechanical Engineering, Yuan-Ze University, Chung Li, Taiwan
Chang-Tsair Chang
Department of Mechanical Engineering, Yuan-Ze University, Chung Li, Taiwan
Yu-Juei Chang
Energy and Resources Laboratories, Industrial Technology Research Institute, Hsinchu, Taiwan

RÉSUMÉ

The paper presents the results of an experimental study on the air-side performance for two-specific louver fin patterns and their plain fin counterpart. The corresponding longitudinal tube pitches for the test samples were 19.05 and 22 mm, and the nominal tube diameter for the test samples is 9.52 mm. For plain fin pattern, the effect of longitudinal tube pitch on the air-side performance is negligible whereas the heat transfer performance increases with decrease of fin pitch. For louver fin geometry, both longitudinal tube pitch and fin pitch shows very small effect on the heat transfer performance. However, it is found that the heat transfer coefficients for Fp = 1.78 mm are approximately 0 ∼ 10% higher than those of Fp = 1.21 mm and Fp = 2.42 mm. In addition, compared with P1 = 19.05 mm, significant increase of friction factors were observed for the louver fin pattern.


Articles with similar content:

PERFORMANCE CHARACTERISTICS OF DEEP CORRUGATED TUBES WITH TWISTED-TAPE INSERTS
Journal of Enhanced Heat Transfer, Vol.19, 2012, issue 1
Arthur E. Bergles, Ventsislav D. Zimparov, Valentin Metodiev Petkov
Calculation of Convective Heat Transfer of Plane Surfaces with Wire-Net Finning Immersed in a Cross-Flow
Heat Transfer Research, Vol.36, 2005, issue 1&2
A. M. Terekh, V. A. Rogachov, E. N. Pis'mennyi, A. I. Rudenko, V. D. Burlei
ON THE HEAT AND MASS ANALOGY OF FIN-AND-TUBE HEAT EXCHANGERS
International Heat Transfer Conference 13, Vol.0, 2006, issue
Chi-Chuan Wang
ENHANCEMENT OF HEAT TRANSFER BY A COMBINATION OF A SINGLE START SPIRALLY CORRUGATED TUBES WITH A TWISTED TAPE
ICHMT DIGITAL LIBRARY ONLINE, Vol.1, 2000, issue
Ventsislav D. Zimparov
Abstract of "ENHANCEMENT OF HEAT TRANSFER BY A COMBINATION OF A SINGLE START SPIRALLY CORRUGATED TUBES WITH A TWISTED TAPE"
ICHMT DIGITAL LIBRARY ONLINE, Vol.1, 2000, issue
Ventsislav D. Zimparov