Journal of Enhanced Heat Transfer
Facteur d'impact: 0.562 Facteur d'impact sur 5 ans: 0.605 SJR: 0.175 SNIP: 0.361 CiteScore™: 0.33

ISSN Imprimer: 1065-5131
ISSN En ligne: 1026-5511

Volumes:
Volume 26, 2019 Volume 25, 2018 Volume 24, 2017 Volume 23, 2016 Volume 22, 2015 Volume 21, 2014 Volume 20, 2013 Volume 19, 2012 Volume 18, 2011 Volume 17, 2010 Volume 16, 2009 Volume 15, 2008 Volume 14, 2007 Volume 13, 2006 Volume 12, 2005 Volume 11, 2004 Volume 10, 2003 Volume 9, 2002 Volume 8, 2001 Volume 7, 2000 Volume 6, 1999 Volume 5, 1998 Volume 4, 1997 Volume 3, 1996 Volume 2, 1995 Volume 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.v24.i1-6.200
pages 279-290

MEASUREMENT OF CONDENSATE FILM THICKNESS FOR SOLUTAL MARANGONI CONDENSATION

Yoshio Utaka
Yokohama National University, Department of Mechanical Engineering, Tokyo Institute of Technology 2-12-1 0-okayama, Meguro-ku Tokyo 152 JAPAN; School of Mechanical Engineering, Tianjin University, 135 Ya Guan Rd. Tianjin Haihe Education Park, Jinnan District, Tianjin300350, China; Key Laboratory of Efficient Utilization of Low and Medium Grade Energy (Tianjin University), Ministry of Education, China
Tetsuji Nishikawa
Air Liquide Japan

RÉSUMÉ

During solutal Marangoni dropwise condensation of a water–ethanol vapor mixture, condensation was observed by a high-speed camera while condensate film thickness was measured by the laser light extinction method. Good correspondence was observed between the film thickness data and the observed condensate behaviors. Minimum condensate film thickness occurred immediately after a departing drop swept by and decreased with increasing initial drop distance in the steep increase region of the condensation characteristic curve. In the region of higher cooling intensity, both initial drop distance and minimum condensate thickness increased with cooling intensity. The smallest thickness of the condensate film was less than 1 μm. A close relationship was confirmed to exist among condensate film thickness, initial drop distance, and heat transfer characteristics.


Articles with similar content:

Measurement of Condensate Film Thickness for Solutal Marangoni Condensation Applying Laser Extinction Method
Journal of Enhanced Heat Transfer, Vol.10, 2003, issue 2
Yoshio Utaka, Tetsuji Nishikawa
Unsteady Measurement of Condensate Film Thickness for Solutal Marangoni Condensation
International Heat Transfer Conference 12, Vol.44, 2002, issue
Yoshio Utaka, Tetsuji Nishikawa
Characteristics of Flow Boiling Heat Transfer in Rectangular Minichannels
International Heat Transfer Conference 15, Vol.16, 2014, issue
Chaobin Dang, Eiji Hihara, Chitose Tanaka
DRYOUT OF LIQUID FILM IN HIGH QUALITY R-113 UPFLOW IN A HEATED TUBE
International Heat Transfer Conference 6, Vol.1, 1978, issue
Yasuo Koizumi, Hiroaki Tanaka , Tatsuhiro Ueda
A STUDY ON MARANGONI CONDENSATION (MEASUREMENT AND OBSERVATION FOR WATER AND ETHANOL VAPOR MIXTURE)
International Heat Transfer Conference 11, Vol.17, 1998, issue
Tatsuya Kenmotsu, Shunya Yokoyama, Yoshio Utaka