Volume 26, 2019 Volume 25, 2018 Volume 24, 2017 Volume 23, 2016 Volume 22, 2015 Volume 21, 2014 Volume 20, 2013 Volume 19, 2012 Volume 18, 2011 Volume 17, 2010 Volume 16, 2009 Volume 15, 2008 Volume 14, 2007 Volume 13, 2006 Volume 12, 2005 Volume 11, 2004 Volume 10, 2003 Volume 9, 2002 Volume 8, 2001 Volume 7, 2000 Volume 6, 1999 Volume 5, 1998 Volume 4, 1997 Volume 3, 1996 Volume 2, 1995 Volume 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.v24.i1-6.60
pages 101-116

HEAT TRANSFER IN SQUARE CHANNELS WITH WEDGE-SHAPED AND DELTA-SHAPED TURBULENCE PROMOTERS

Je-Chin Han
Turbine Heat Transfer Laboratory, Department of Mechanical Engineering, Texas A&M University College Sation, TX 77843-3123, USA
J. Joy Huang
Department of Mechanical Engineering, Texas A & M University, College Station, Texas 77843-3123
Ching-Pang Lee
General Electric Company, Cincinnati, Ohio 45215, U.S.A.

RÉSUMÉ

The effect of rib configuration on local heat transfer coefficients and pressure drop in a square channel with two opposite in-line ribbed walls was investigated at Reynolds numbers from 15,000 to 80,000. Two types of rib configurations were studied. The first group is a wedge-shaped rib with the rib height-to-hydraulic diameter ratio of 0.125 and the rib pitch-to-height ratio of 5 or 10. Both full length and broken ribs are studied. The second group is a delta-shaped rib with the rib height-to-hydraulic diameter ratio of 0.125 and the rib pitch-to-height ratio of 5. Both aligned and offset arrangements are studied for a forward and backward direction relative to the mainstream flow. Results show that, for the delta-shaped rib, the backward flow direction has higher heat transfer than the forward flow direction, and the aligned arrangement is better than the offset arrangement. The broken configuration for the wedge-shaped rib performs better than the full length one. In general, the delta-shaped rib performs better than the wedge-shaped rib. The backward delta-shaped aligned rib configuration produces the highest heat transfer augmentation (3-4 times), while the backward delta-shaped offset rib creates the smallest pressure drop penalty (5-6 times). Results also show that the surface heat flux ratio has significant effect on the smooth-side heat transfer augmentation, while the effect on the ribbed-side is relatively small.


Articles with similar content:

Augmented Heat Transfer in Square Channels with Wedge-Shaped and Delta-Shaped Turbulence Promoters
Journal of Enhanced Heat Transfer, Vol.1, 1994, issue 1
Je-Chin Han, J. Joy Huang, Ching-Pang Lee
NUMERICAL PREDICTIONS OF PRESSURE DROP AND HEAT TRANSFER IN A BLADE INTERNAL COOLING PASSAGE WITH CONTINUOUS/TRUNCATED RIBS
Heat Transfer Research, Vol.43, 2012, issue 6
Bengt Sunden, Gongnan Xie, Weihong Zhang, Shian Li
Pressure Drop Characteristics in a Rib Roughened Rotating Square Duct with a Sharp 180° Bend
Journal of Enhanced Heat Transfer, Vol.10, 2003, issue 4
Santosh V. Prabhu, R. P. Vedula
An Experimental Study of Heat Transfer in the Turn Region of a U-Bend channel with Various Ribs
International Heat Transfer Conference 15, Vol.23, 2014, issue
Lei Wang, Bengt Sunden, Chenglong Wang
FRICTION AND HEAT TRANSFER CHARACTERISTICS OF TURBULENT FLOW IN A HELICAL VANE FITTED ANNULUS ROTATING ABOUT A PARALLEL AXIS
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2015, issue
Anil W. Date