Volume 29, 2019 Volume 28, 2018 Volume 27, 2017 Volume 26, 2016 Volume 25, 2015 Volume 24, 2014 Volume 23, 2013 Volume 22, 2012 Volume 21, 2011 Volume 20, 2010 Volume 19, 2009 Volume 18, 2008 Volume 17, 2007 Volume 16, 2006 Volume 15, 2005 Volume 14, 2004 Volume 13, 2003 Volume 12, 2002 Volume 11, 2001 Volume 10, 2000 Volume 9, 1999 Volume 8, 1998 Volume 7, 1997 Volume 6, 1996 Volume 5, 1995 Volume 4, 1994 Volume 3, 1993 Volume 2, 1992 Volume 1, 1991

Atomization and Sprays

DOI: 10.1615/AtomizSpr.v19.i11.10
pages 997-1012

NEAR-WALL CHARACTERISTICS OF AN IMPINGING GASOLINE SPRAY AT INCREASED AMBIENT PRESSURE AND WALL TEMPERATURE

Jochen Stratmann
Institute of Heat and Mass Transfer, RWTH Aachen University, Germany
D. Martin
Institute of Heat and Mass Transfer, RWTH Aachen University, Eilfschornsteinstr. 18, 52062 Aachen, Germany
P. Unterlechner
Institute of Heat and Mass Transfer, RWTH Aachen University, Eilfschornsteinstr. 18, 52062 Aachen, Germany
Reinhold Kneer
Institute of Heat and Mass Transfer, RWTH Aachen University, Augustinerbach 6, 52062 Aachen, Germany

RÉSUMÉ

With a focus on the direct-injection gasoline (GDI) engine, this work provides near-wall spray details of the liquid phase of an impinging fuel spray at GDI engine conditions. The experiments are conducted in a constant volume pressure chamber at elevated gas pressure (pgas = 0.6 and 1.5 MPa), increased gas temperature (Tgas = 500 K), and variable wall temperature (Tw = 400 and 575 K). Using phase-Doppler anemometry, temporally and spatially resolved mean droplet sizes and velocity components are determined at distances from 0.2 to 1.0 mm above the surface. The transient behavior of the wall jet, which develops along the surface, is resolved by the measurements. The formation of a vortex at the front of this jet is observed. At its tip, large mean droplet diameters are observed that coincide with a rapid change of the wall-normal velocity. An increasing wall temperature causes the tip of the wall jet to propagate slower along the wall, which is apparently caused by a change in the local density of the gas above the surface.


Articles with similar content:

STRUCTURE OF REACTING AND NONREACTING, NONSWIRLING, AIR-ASSISTED SPRAYS, PART II: DROP BEHAVIOR
Atomization and Sprays, Vol.3, 1993, issue 4
M. Adachi, G. Scott Samuelsen, Vincent McDonell
Numerical investigation of ignition characteristics in a HCCI configuration
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2018, issue
Mamoru Tanahashi, Masayasu Shimura, Yuki Minamoto, Y. Kondo
THE EFFECT OF MASS FLOW RATE ON FLOW BEHAVIOUR IN A CENTRIFUGAL IMPELLER PASSAGE
Transport Phenomena in Thermal Engineering. Volume 2, Vol.0, 1993, issue
N. A. Ahmed, R. L. Elder
Dynamics of an Airblast Spray in a Double Swirled Stabilized Flame
International Journal of Fluid Mechanics Research, Vol.28, 2001, issue 6
Redjem Hadef
STRUCTURE OF REACTING AND NONREACTING, NONSWIRLING, AIR-ASSISTED SPRAYS, PART I: GAS-PHASE PROPERTIES
Atomization and Sprays, Vol.3, 1993, issue 4
M. Adachi, G. Scott Samuelsen, Vincent McDonell