Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
Atomization and Sprays
Facteur d'impact: 1.189 Facteur d'impact sur 5 ans: 1.596 SJR: 0.814 SNIP: 1.18 CiteScore™: 1.6

ISSN Imprimer: 1044-5110
ISSN En ligne: 1936-2684

Volumes:
Volume 29, 2019 Volume 28, 2018 Volume 27, 2017 Volume 26, 2016 Volume 25, 2015 Volume 24, 2014 Volume 23, 2013 Volume 22, 2012 Volume 21, 2011 Volume 20, 2010 Volume 19, 2009 Volume 18, 2008 Volume 17, 2007 Volume 16, 2006 Volume 15, 2005 Volume 14, 2004 Volume 13, 2003 Volume 12, 2002 Volume 11, 2001 Volume 10, 2000 Volume 9, 1999 Volume 8, 1998 Volume 7, 1997 Volume 6, 1996 Volume 5, 1995 Volume 4, 1994 Volume 3, 1993 Volume 2, 1992 Volume 1, 1991

Atomization and Sprays

DOI: 10.1615/AtomizSpr.v20.i8.30
pages 697-720

VISCOELASTIC AIR-BLAST SPRAYS IN A CROSS-FLOW. PART 1: PENETRATION AND DISPERSION

Larry Li
Sheldon I. Green
Department of Mechanical Engineering, University of British Columbia, 3321−2260 West Mall, Vancouver, British Columbia, V6T1Z4, Canada
Martin H. Davy
Department of Mechanical Engineering, University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, British Columbia, V6T1Z4, Canada
Donald T. Eadie
Kelsan Technologies Corporation, 1140 West 15th Street, North Vancouver, British Columbia, V7P 1M9, Canada

RÉSUMÉ

Viscoelastic liquids, such as paints and coatings, are widely known to be more difficult to atomize than typical Newtonian liquids. What is not known, however, is how such a difference affects spray coating in field conditions. To address this, we have examined the effect of a cross-flow on two different air-blast sprays, one comprising water and the other an industrial coating. Using particle image velocimetry and raw Mie scattering, we measured the penetration and dispersion of both sprays over a wide range of spray:cross-flow momentum-flux ratios: 134 ≤ qab ≤ 1382. For both sprays, increasing the relative momentum-flux of the cross-flow led to reduced penetration but enhanced dispersion. The leeward boundary, meanwhile, consistently outspread the windward boundary, creating a bias for which we have proposed several plausible mechanisms. As for differences between the two sprays, the coating droplets outpenetrated the water droplets because they had lower drag-momentum ratios, due to their larger size. In response to this finding, we have proposed a new regression model for predicting the penetration of sprays differing in mean droplet size. The coating spray also spread later and more abruptly than did the water spray, particularly at low qab. To explain this behavior, we have suggested a physical mechanism based on the delayed breakup of the coating ligaments.


Articles with similar content:

VISCOELASTIC AIR-BLAST SPRAYS IN A CROSS-FLOW. PART 2: DROPLET VELOCITIES
Atomization and Sprays, Vol.20, 2010, issue 8
Martin H. Davy, Larry Li, Donald T. Eadie, Sheldon I. Green
BAYESIAN NONPARAMETRIC GENERAL REGRESSION
International Journal for Uncertainty Quantification, Vol.6, 2016, issue 3
Gilberto A. Ortiz, Ka Veng Yuen
EFFECT OF SOLID PARTICLE CHARACTERISTICS ON SUSPENSION ATOMIZATION
Atomization and Sprays, Vol.13, 2003, issue 2&3
Gunther Schulte, Basel Mulhem
VISCOSITY AND SURFACE TENSION EFFECTS IN PRESSURE SWIRL ATOMIZATION
Atomization and Sprays, Vol.5, 1995, issue 3
V. Dorfner, Joachim Domnick, Franz Durst, R. Kohler
EFFECT OF NOZZLE GEOMETRY ON THE ATOMIZATION AND SPRAY CHARACTERISTICS OF GELLED-PROPELLANT SIMULANTS FORMED BY TWO IMPINGING JETS
Atomization and Sprays, Vol.20, 2010, issue 12
Jong Guen Lee, Syed Fakhri, Richard A. Yetter