Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
International Journal of Energy for a Clean Environment
SJR: 0.195 SNIP: 0.435 CiteScore™: 0.74

ISSN Imprimer: 2150-3621
ISSN En ligne: 2150-363X

International Journal of Energy for a Clean Environment

Précédemment connu sous le nom Clean Air: International Journal on Energy for a Clean Environment

DOI: 10.1615/InterJEnerCleanEnv.2013005893
pages 309-318

THEORETICAL STUDY OF THE COMBINED M-CYCLE/EJECTOR AIR-CONDITIONING SYSTEM

Dmytro Buyadgie
Wilson, 25, Mikhailovskaya Street, 65005, Odessa, Ukraine; Sustainable Refrigeration Technology Centre, Dvoryanskaya Str. 1/3, Odessa, 65026, Ukraine
Olexiy Buyadgie
Wilson Engineering Technologies Inc./V.S. Martynovsky Institute of Refrigeration, Cryogenic Technologies and Eco Energetics
Oleksii Drakhnia
Wilson, 25, Mikhailovskaya Street, 65005, Odessa, Ukraine; Sustainable Refrigeration Technology Centre, Dvoryanskaya Str. 1/3, Odessa, 65026, Ukraine
Yehor Sladkovskyi
Wilson, 25, Mikhailovskaya Street, 65005, Odessa, Ukraine; Sustainable Refrigeration Technology Centre, Dvoryanskaya Str. 1/3, Odessa, 65026, Ukraine
Sergiy V. Artemenko
Computer Engineering Department, V.S. Martynovsky Insititute of Refrigeration, Cryogenic Technologies and Eco Energetics, Odessa National Academy of Food Technologies, 1/3, Dvoryanskaya Str., Odessa 65026, Ukraine
Andrei Chamchine
Division of Energy, Fire and Sustainability, School of Engineering, University of Central Lancashire, Preston PR1 2HE, UK

RÉSUMÉ

The Maisotsenko cycle (M-cycle) for air-conditioning technologies offers opportunities for energy conservation and reduction of greenhouse gas emissions. It also improves the quality of the cooled air without additional inputs for the return air system.
The high efficiency of the M-cycle is observed at low relative humidity of the outside air, which restricts the M-cycle detached application. Obviously, an application of the M-cycle paired with conventional electrically-driven cooling systems will worsen energy characteristics due to the compressor work required. If the ejector refrigerating system (ERS) is combined with the M-cycle, the overall system performance increases as described in this paper. The combination of the M-cycle with ejector-based cooling systems explores application spheres of the M-cycle associated air conditioners.


Articles with similar content:

ELECTROSTATIC ENFORCEMENT OF HEAT EXCHANGE IN THE MAISOTSENKO‐CYCLE SYSTEM
International Journal of Energy for a Clean Environment, Vol.12, 2011, issue 2-4
Michael Reznikov
Optimal Sizing of Heat Exchangers for Organic Rankine Cycles (ORC) Based on Thermo-Economics
International Heat Transfer Conference 15, Vol.43, 2014, issue
Steven Lecompte, Martijn Van den Broek, Michel De Paepe
PERFORMANCE ANALYSIS OF A METAL HYDRIDE-THERMAL ENERGY STORAGE SYSTEM FOR CONCENTRATING SOLAR POWER PLANTS
4th Thermal and Fluids Engineering Conference, Vol.31, 2019, issue
Sofiene Mellouli, Talal Alqahtani, Faouzi Askri, Patrick E. Phelan
PERFORMANCE ANALYSIS OF A MAISOTSENKO CYCLE-BASED ENERGY-EFFICIENT EVAPORATIVE AIR CONDITIONER
International Journal of Energy for a Clean Environment, Vol.12, 2011, issue 2-4
Satyashree Ghodke, Chandrakant Wani
Thermoelectric Generator Utilizing Automobile Engine Exhaust Gas (Numerical Simulation and Optimum Fin Arrangement)
International Heat Transfer Conference 12, Vol.48, 2002, issue
Michio Morishita, Hirokazu Yamane, Masaru Ooishi, Masahide Miyamoto


You do not have access to this article. Please purchase the article, or logon and check your subscription