Library Subscription: Guest
Begell Digital Portal Begell Digital Library eBooks Journals References & Proceedings Research Collections
Journal of Long-Term Effects of Medical Implants
SJR: 0.133 SNIP: 0.491 CiteScore™: 0.89

ISSN Print: 1050-6934
ISSN Online: 1940-4379

Journal of Long-Term Effects of Medical Implants

DOI: 10.1615/JLongTermEffMedImplants.v17.i4.60
pages 321-334

Can Ultrastructural Particle Location Predict Aseptic Loosening? A Biopsy Study of Nonloose Hip Implants One Year Postoperative Using Three Bearing Material Combinations

Marianne Nygaard
Department of Orthopaedic Surgery, Frederiksberg University Hospital, Denmark
L. Bastholm
Institute of Molecular Pathology, University of Copenhagen, Denmark
F. Elling
Institute of Molecular Pathology, University of Copenhagen, Denmark
Kjeld Soballe
Orthopedic Research Laboratory, Norrebrogade 44 big 1A, University Hospital of Aarhus, 8000 Arhus C, Denmark
A. Borgwardt
Department of Orthopaedic Surgery, Frederiksberg University Hospital, Denmark

ABSTRACT

To find predisposing parameters for aseptic loosening the present study determined the ultrastructural morphology in the pseudosynovial membrane from non-loose hip arthroplasties to compare the intra- and extracellular distribution of wear particles one year after total hip replacement using three different bearing material combinations.A total of 37 patients from a larger prospective randomised trial of 225 patients had biopsies taken arthroscopically from the pseudosynovial membrane one year after insertion of identical endoprostheses except for the bearing materials, polyethylene-on-zirconia (n=15), alumina-on-alumina (n=13), and CoCr-CoCr (n=9), respectively. The granulomatous inflammation seen in biopsies from these well-fixated implants was qualitatively comparable to the pattern seen in aseptic loose implants. Wear particles were seen in the extracellular matrix and intracellularily in macrophages, fibroblasts, and in endothelial cells. It was not possible systematically to distinguish the morphology between the three groups, though in one patient with CoCr-CoCr bearing material necrotic tissue was seen and exclusively extracellular location was not found in this group. The transport mechanism may vary with these materials and particle number. At this initial stage after hip surgery, the present study did not provide evidence for different types of bearing materials having significant impact on ultrastructural morphology adjacent to hip arthroplasties within the first year after surgery.


Articles with similar content:

Application of the Finite Element Method in Orthopedic Implant Design
Journal of Long-Term Effects of Medical Implants, Vol.19, 2009, issue 1
Amit Roychowdhury
10-Year Evaluation of the Cementless Low-Contact- Stress Rotating-Platform Total Knee Arthroplasty
Journal of Long-Term Effects of Medical Implants, Vol.19, 2009, issue 4
Vassilios Nikolaou, Demetrios S. Korres, Olga D. Savvidou, Panayiotis J. Papagelopoulos, Stergios N. Lallos, Nikolaos E. Efstathopoulos, Andreas F. Mavrogenis
Evidence That In Vivo Wear Damage Alters Kinematics and Contact Stresses in a Total Knee Replacement
Journal of Long-Term Effects of Medical Implants, Vol.20, 2010, issue 1
David W. Holdsworth, John L. Williams, Matthew G Teeter, David A. Knox, William M. Mihalko
Correlative Experimental Animal and Human Clinical Retrieval Evaluations of Hydroxyapatite (HA)-Coated and Non-Coated Implants in Orthopaedics and Dentistry
Critical Reviews™ in Biomedical Engineering, Vol.28, 2000, issue 3&4
David E. Steflik, Raymond Y. Whitehead, Michael D. Wilson, Carlos Jaramillo, Timothy R. Young, R. Scott Corpe
Comparison of Stress Distribution in Alveolar Bone with Different Implant Diameters and Vertical Cantilever Length via the Finite Element Method
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 1
Mahsa Rashidpour, Paniz Fasihg, Niloufar Ahmadian, Ashraf Sayyedi, Mohammad Dehghan, Forouzan Faghani, Amir Fayyaz