THERMAL PERFORMANCE OF CLOSED LOOP PULSATING HEAT PIPE: AN EXPERIMENTAL STUDY WITH VISUALIZATION

Pramod R. Pachghare
Department of Mechanical Engineering, Government College of Engineering, Amravati-444604, India
Ashish M. Mahalle
Department of General Engineering, Laxminarayan Institute of Technology, Nagpur-444001, India; Department of Mechanical Engineering, Government College of Engineering, Amaravati, Maharashtra, India

ABSTRACT

This paper present preliminary the experimental results on the thermal performance of closed loop pulsating heat pipes (CLPHPs) using pure and binary working fluids. The CLPHP is made of copper capillary tubes, having inner and outer diameters are 2.0mm and 3.6mm respectively. The working fluids are employed as water, ethanol, methanol and acetone also binary mixture (1:1 by volume) of water-ethanol, water-methanol and water-acetone. For all experimentations, filling ratio (FR) 50%, two-turns and vertical bottom heat mode position was maintained. The lengths of evaporator, condenser and adiabatic section are 42mm, 50mm and 170mm respectively. The adiabatic section has partially made up of glass tube, having length 80mm, to assist flow visualization. The results shows that, thermal resistance are decreases smoothly upto 40W heat input, thereafter reasonably steady. Binary working fluid shows the better thermal performance in comparison to its pure constituents. Water-acetone binary working fluid has shown the best thermal performance over other working fluid. The thermal performance (i.e., overall thermal resistance) is strongly dependent on the flow pattern existing inside the tubes.


Articles with similar content:

AN EXPERIMENTAL INVESTIGATION ON THE PERFORMANCE OF CLOSED LOOP PULSATING HEAT PIPE
Heat Pipe Science and Technology, An International Journal, Vol.5, 2014, issue 1-4
Prasanta Kumar Das, Nandan Saha, P. K. Sharma
EXPERIMENTAL INVESTIGATION OF CLOSED LOOP PULSATING HEAT PIPE USING AMMONIA FLUID: EFFECT OF INCLINATION
Heat Pipe Science and Technology, An International Journal, Vol.5, 2014, issue 1-4
Jijun Yu, Minghui Xie , Wei Qu, Zhihu Xue, Wei Li
PERFORMANCE EXPERIMENT FOR ANEW TYPE OF CPL SYSTEM
International Heat Transfer Conference 13, Vol.0, 2006, issue
Zhichun Liu, Jinguo Yang, Xiaobing Luo, Wei Liu
Pulsating Heat Pipes: Thermo-fluidic Characteristics and Comparative Study with Single Phase Thermosyphon
International Heat Transfer Conference 12, Vol.54, 2002, issue
Sameer Khandekar, P. Charoensawan, Manfred Groll, Pradit Terdtoon
EXPERIMENTAL INVESTIGATIONS OF AN INTERNALLY FINNED TWO PHASE CLOSED VERTICAL WICKLESS HEAT PIPE CHARGED WITH METHANOL, ETHANOL AND BINARY FLUIDS
Proceedings of the 24th National and 2nd International ISHMT-ASTFE Heat and Mass Transfer Conference (IHMTC-2017), Vol.0, 2017, issue
Chakravarthy Balaji, Naresh Yarramsetty