pages 527-536

A FEASIBILITY STUDY OF APPLYING PULSATING HEAT PIPE IN HEAT SINK

Zirong Lin
Key Laboratory of Enhanced Heat Transfer and Energy Conservation of the Ministry of Education, South China University of Technology, Guangzhou 510640, China
Shuangfeng Wang
Key Laboratory of Enhanced Heat Transfer and Energy Conservation of the Ministry of Education, School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou 510640, Guangdong, PR China
Winston Zhang
Novark Technology, Inc, Shenzhen, China
Eton Lee
Novark Technology, Inc, Shenzhen, China
Xianyong Zeng
Novark Technology, Inc, Shenzhen, China
Yong Tang
Key Laboratory of Surface Functional Structure Manufacturing of Guangdong Higher Education Institutes, South China University of Technology, Guangzhou 510640, China

ABSTRACT

An experimental investigation was carried out for the feasibility of applying pulsating heat pipe (PHP) in processor unit cooling. Copper tubes with an external diameter of 2.5 mm and inner diameter of 1.3 mm were used for PHP manufacturing. The heat transport characteristics of the PHP were explored. It was proved that PHP is promising to use in handling high-power dissipation. The thermal performance of PHPs in different structures (U-shaped, L-shaped, and flat-shaped) were tested and the U-shaped PHP (where two ends are bent as a condensation section with a central evaporation section) was considered to be the best one. Therefore, the U-shaped PHP was chosen to develop a thermal module−a new type of PHP heat sink design. Compared to a conventional finned heat sink design and a heat pipe embedded solution, the advantages of the new PHP heat sink design became obvious under high-power heating, and kept a lower and stable thermal resistance. Its thermal resistance was equal to 0.68 K/W, when the heating power was 200 W and the heating contact area was 14 × 14 mm. Judging from the inflection point of the temperature curve of the PHP heat sink, it was considered that a larger proportion of heat was transported by latent heat.


Articles with similar content:

THERMAL PERFORMANCE OF RE-ENTRANT GROOVE HEAT PIPE: DEPENDENCE ON ORIENTATION AND TEMPERATURE
Heat Pipe Science and Technology, An International Journal, Vol.5, 2014, issue 1-4
Yasuko Shibano, Hiroyuki Ogawa
Structural Optimization of Axially Grooved Flat Miniature Heat Pipes
Journal of Enhanced Heat Transfer, Vol.7, 2000, issue 6
Yiding Cao, B. Donovan, Jerry E. Beam, M. Gao
EFFECTS OF CROSS-SECTION GEOMETRY ON THE THERMAL PERFORMANCE OF A PULSATING HEAT PIPE
First Thermal and Fluids Engineering Summer Conference, Vol.15, 2015, issue
Sungwan Park, Jungseok Lee, Sung Jin Kim
Comparison of Aluminium Foam Finned Heat Sinks and Effect of Painting and Orientation in Buoyancy-Driven Convection
International Heat Transfer Conference 15, Vol.40, 2014, issue
Henk Huisseune, Michel De Paepe, Sven De Schampheleire, Kathleen De Kerpel, Gerben Kennof, Pieter Pirmez
AN EXPERIMENTAL STUDY ON PERFORMANCE ENHANCEMENT OF CMOS COMPATIBLE MONOLITHIC MICROCHANNEL HEAT SINKS
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2014, issue
Tuba Okutucu-Ozyurt, Haluk Kulah, Satish Kumar, Aziz Koyuncuoglu, Goker Turkakar, Matthew Redmond