Histomorphometric Comparison of Transmandibular Implant and Titanium Implant

巻 26, 発行 3, 2016, pp. 209-215
DOI: 10.1615/JLongTermEffMedImplants.2016016210
Get accessGet access

要約

This study was a histomorphometric comparison of the transmandibular implant (TMI) system and titanium implant using a confocal laser scanning microscope (CLSM). Two dogs were used. In each dog, 16 implant holes were made in the bilateral mandibular angle. Four cortical screws in the TMI, four titanium plasma spray (TPS) implants, and four hydroxyapatite (HA) coating implants were inserted and four holes were left as a control. Two dogs were sacrificed at 3 and 6 months. The samples were cut longitudinally and examined under CLSM. The contact rate of trabecular bone was smaller than that of cortical bone in all implants. The contact rates in TMI at 3 and 6 months was significantly smaller than those of TPS and HA and there was no difference between TPS and HA. Although the contact rate of TMI was low, only a small contact area may be enough for TMI because of its box form structure.

573 記事の閲覧数 22 記事のダウンロード 記事の統計
573 記事の閲覧数 22 記事のダウンロード Google
Scholar
引用数

類似内容の記事:

Correlative Experimental Animal and Human Clinical Retrieval Evaluations of Hydroxyapatite (HA)-Coated and Non-Coated Implants in Orthopaedics and Dentistry Critical Reviews™ in Biomedical Engineering, Vol.28, 2000, issue 3&4
David E. Steflik, Raymond Y. Whitehead, Michael D. Wilson, Carlos Jaramillo, Timothy R. Young, R. Scott Corpe
High Insertion Torque and Peri-Implant Bone Loss: Is There a Relationship? Journal of Long-Term Effects of Medical Implants, Vol.25, 2015, issue 3
Mohsen Bidgoli, Javad Faradmal, Sepideh Soheilifar, Sara Soheilifar
Metal Sensitivities Among TJA Patients with Post-Operative Pain: Indications for Multi-Metal LTT Testing Journal of Long-Term Effects of Medical Implants, Vol.24, 2014, issue 1
Edward Solver, Marco S. Caicedo, Nadim James Hallab, Latasha Coleman
Hydroxyapatite and Carbon Coatings for Fixation of Unloaded Titanium Implants Journal of Long-Term Effects of Medical Implants, Vol.14, 2004, issue 6
Mikael Sundfeldt, Olav Reikeras, Carina B. Johansson
Histological Evaluation, in Rabbit Tibiae, of Osseointegration of Mini-implants in Sites Prepared with Er:YAG Laser versus Sites Prepared with Traditional Burs Journal of Long-Term Effects of Medical Implants, Vol.16, 2006, issue 2
Sergio Salina, Giovanna Iezzi, Alessandro Colombo, Carlo Maiorana, Filippo Fontana, Adriano Piattelli

近刊の記事

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Begell Digital Portal Begellデジタルライブラリー 電子書籍 ジャーナル 参考文献と会報 リサーチ集 価格及び購読のポリシー Begell House 連絡先 Language English 中文 Русский Português German French Spain