ライブラリ登録: Guest
Journal of Long-Term Effects of Medical Implants

年間 4 号発行

ISSN 印刷: 1050-6934

ISSN オンライン: 1940-4379

SJR: 0.184 SNIP: 0.485 CiteScore™:: 1.1 H-Index: 39

Indexed in

Regional Measurements of Surface Deviation Volume in Worn Polyethylene Joint Replacement Components

巻 20, 発行 1, 2010, pp. 49-56
DOI: 10.1615/JLongTermEffMedImplants.v20.i1.70
Get accessGet access

要約

Total joint replacements can be subject to the loss of polyethylene material due to wear, leading to osteolysis and decreased implant longevity. Micro-computed tomography (micro-CT) techniques have recently been developed to calculate 3D surface deviations in worn implant components. We describe a micro-CT technique to measure the volume of the surface deviations (volume of wear plus creep) within a specific region or compartment, and report its repeatability and reproducibility. Six worn polyethylene tibial inserts were scanned using a laboratory micro-CT scanner and subsequently reconstructed at 50 μm voxel spacing. A previously developed custom software application was used to quantify the 3D surface deviations between the worn tibial inserts and an unworn reference geometry. Three observers (two trained and one expert) used new custom software to manually outline the localized regions of surface deviation (three times for each of the worn inserts) and calculate the volume of the deviations. The overall intrao- bserver variability in the surface deviation volumes was 3.6% medially and 1.1% laterally. The overall in- terobserver variability was 4.8% medially and 1.7% laterally. Placement of points in outlining the region of deviation contributed the greatest variability to the measurements. Repeatability and reproducibility of the volume measurements are similar to measurements of total (nonregional) wear volume including a previous micro-CT technique (10%), fluid displacement (4.8%), and radiographic measurements (15.7%). The principles of this technique can likely be used to measure regional wear and creep volume in knee and hip joint replacement components from wear simulator, pin-on-disk, and retrieval studies.

によって引用された
  1. Teeter Matthew G, Seslija Petar, Milner Jaques S, Nikolov Hristo N, Yuan Xunhua, Naudie Douglas D R, Holdsworth David W, Quantification ofin vivoimplant wear in total knee replacement from dynamic single plane radiography, Physics in Medicine and Biology, 58, 9, 2013. Crossref

  2. Teeter Matthew G, Langohr G Daniel G, Medley John B, Holdsworth David W, Nondestructive microimaging during preclinical pin-on-plate testing of novel materials for arthroplasty, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 228, 2, 2014. Crossref

  3. Cerquiglini Arianna, Henckel Johann, Hothi Harry S., Dall'Ava Lorenzo, Shearing Paul, Hirschmann Michael T., Hart Alister J., Computed Tomography Techniques Help Understand Wear Patterns in Retrieved Total Knee Arthroplasty, The Journal of Arthroplasty, 33, 9, 2018. Crossref

  4. Day Judd S., Abboud Joseph A., Implant Retrieval, in Reverse Shoulder Arthroplasty, 2016. Crossref

406 記事の閲覧数 33 記事のダウンロード 記事の統計
406 記事の閲覧数 33 記事のダウンロード 4 Crossref 引用数 Google
Scholar
引用数

類似内容の記事:

Measurements of Surface and Subsurface Damage in Retrieved Polyethylene Tibial Inserts of a Contemporary Design Journal of Long-Term Effects of Medical Implants, Vol.22, 2012, issue 1
Jan-M. Brandt, David W. Holdsworth, Matthew G Teeter, Eric R. Bohm, Douglas D. R. Naudie, Richard W. McCalden
Clinical Evaluation of a New Total Hip Prosthetic Design: 100 Consecutive Cementless Total Hip Arthroplasties Using Sulzermedica's "Natural Hip" With Two- to Six-Year Clinical and Radiographic Follow-Up Critical Reviews™ in Biomedical Engineering, Vol.28, 2000, issue 1&2
Thomas B. Pace
Cervical Spine Fusion: Biomechanics of a Three-Level Cadaver Model Comparing Anterior Plate versus Stand-Alone Cage Journal of Long-Term Effects of Medical Implants, Vol.30, 2020, issue 2
Loren L. Latta, Wood Dale, Robert McGuire, Abeer Al-Barghouthi, Francesco Travascio
Ramus Frame Dental Implant Functional Survival and Safety in Severely Atrophic Edentulous Human Mandibles Journal of Long-Term Effects of Medical Implants, Vol.34, 2024, issue 3
O. Hilt Tatum Jr., Thomas E. Rams
Alveolar Ridge Preservation Using the One-Piece Autologous Tuberosity Graft: A Clinical, Radiological, and Histological Pilot Study Journal of Long-Term Effects of Medical Implants, Vol.34, 2024, issue 2
Nabil Ghosn, Carlos Khairallah, Carla Maria Khairallah, Ronald Younes, Christian Makary, Tonino Traini

近刊の記事

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Begell Digital Portal Begellデジタルライブラリー 電子書籍 ジャーナル 参考文献と会報 リサーチ集 価格及び購読のポリシー Begell House 連絡先 Language English 中文 Русский Português German French Spain