Evidence That In Vivo Wear Damage Alters Kinematics and Contact Stresses in a Total Knee Replacement

巻 20, 発行 1, 2010, pp. 43-48
DOI: 10.1615/JLongTermEffMedImplants.v20.i1.60
Get accessGet access

要約

Polyethylene wear after a total knee arthroplasty is inevitable. The effects of the wear particles on the surrounding soft tissue causing inflammatory responses and eventual aseptic loosening are well documented, but the biomechanical changes from polyethylene wear have been less understood. This study investigated how wear from a retrieved polyethylene insert from a total knee arthroplasty changed the kinematics and contact stresses. A cruciate-retaining total knee implant (Natural-Knee, Intermedics Orthopedics, Inc., Austin, Texas) was retrieved from a donor program. The polyethylene insert was then scanned and modeled. KneeSIM (LifeMOD/KneeSIM, San Clemente, California) was used to simulate one cycle of gait of three second duration (100% of cycle). A threefold increase in contact stress as well as resulting kinematic changes were seen when the model was used to compare the retrieved versus a modeled off-the-shelf new polyethylene insert. Total knee designs should take into account the wear patterns that result from years of use and how they may affect the biomechanics of the knee long term.

によって引用された
  1. Chen Zhenxian, Zhang Xuan, Ardestani Marzieh M, Wang Ling, Liu Yaxiong, Lian Qin, He Jiankang, Li Dichen, Jin Zhongmin, Prediction of in vivo joint mechanics of an artificial knee implant using rigid multi-body dynamics with elastic contacts, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 228, 6, 2014. Crossref

  2. Alberts L Russell, Martinez-Nogues Vanesa, Cook Richard Baker, Maul Christian, Bills Paul, Racasan R, Stolz Martin, Wood Robert J K, Technical note: Comparison of metal-on-metal hip simulator wear measured by gravimetric, CMM and optical profiling methods, Surface Topography: Metrology and Properties, 6, 1, 2018. Crossref

  3. Zhang Qida, Chen Zhenxian, Zhang Jing, Hu Jiayu, Peng Yinghu, Fan Xunjian, Jin Zhongmin, Insert conformity variation affects kinematics and wear performance of total knee replacements, Clinical Biomechanics, 65, 2019. Crossref

  4. Van de Kleut Madeleine L., Nair Chaithanya, Milner Jaques S., Holdsworth David W., Athwal George S., Teeter Matthew G., In vivo reverse total shoulder arthroplasty contact mechanics, Journal of Shoulder and Elbow Surgery, 30, 2, 2021. Crossref

  5. Zhang Jing, Chen Zhenxian, Zhang Qida, Jin Zhongmin, Computational modelling of biomechanics and biotribology for artificial knee joint, in Computational Modelling of Biomechanics and Biotribology in the Musculoskeletal System, 2021. Crossref

  6. Zhang Jing, Chen Zhenxian, Wang Ling, Li Dichen, Jin Zhongmin, A patient-specific wear prediction framework for an artificial knee joint with coupled musculoskeletal multibody-dynamics and finite element analysis, Tribology International, 109, 2017. Crossref

近刊の記事

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka