Histological Evaluation, in Rabbit Tibiae, of Osseointegration of Mini-implants in Sites Prepared with Er:YAG Laser versus Sites Prepared with Traditional Burs

Sergio Salina
Consultant Professor, Department of Periodontology and Implantology, University of Milan, Dental Clinic (ICP), Milan, Italy
Carlo Maiorana
Professor and Head, Department of Periodontology and Implantology, University of Milan, Dental Clinic (ICP), Milan, Italy
Giovanna Iezzi
Research Fellow, Dental School, Department of Oral Pathology, University of Chieti, Chieti, Italy
Alessandro Colombo
Research Fellow, Department of Periodontology and Implantology, University of Milan, Dental Clinic (ICP), Milan, Italy
Filippo Fontana
Research Fellow, Department of Periodontology and Implantology, University of Milan, Dental Clinic (ICP), Milan, Italy
Adriano Piattelli
Professor of Oral Medicine and Pathology, Dean and Director of Studies and Research, Dental School, University of Chieti-Pescara, Italy

要約

Objective: The aim of this study was to evaluate the different bone reactions in rabbit tibiae after the insertion of mini-implants by using two different techniques of site preparation: the superpulsed Er:YAG laser (VPS system) versus the traditional technique with burs.
Methods: One mm wide and 2 mm long implant sites were made in the tibiae of 12 rabbits (8 for each tibia): the authors used an Er:YAG laser with a sapphire tip on a contra-angle hand piece with a 1.0 mm diameter in a VPS mode (with 200 mJ and 30 Hz) to make 4 bone sites and a calibrated traditional bur to drill the other 4 sites in each tibia.
The authors inserted a threaded mini-implant, with a sandblasted and acid-etched surface, in the 2 laser implant sites and in the 2 drilled sites of each tibia. The other sites were used as controls. At 0, 7, 15, 30, 45, and 60 days from the surgery, 2 animals each were euthanized, and the retrieved specimens were evaluated.
Results: No implant was lost, and the osseointegration was comparable in all implant sites. Histologically, in the 7- and 15-day postoperative specimens, the laser sites showed some amorphous tissue caused by the carbonization of bone during the laser procedure. The sites without implants showed good regeneration of the bone: it was faster in the drill defects because in the laser ones there was some carbonized amorphous tissue. After 30 days postoperatively, the regeneration was the same in all sites.
Conclusions: In comparison with the traditional drilling procedures, Er:YAG laser can be considered efficient in surgery of the bone without inducing irreversible damages, even if it is possible to observe the presence of some carbonized amorphous tissue in the early part of the healing process. This tissue is progressively resorbed in a way similar to a bone graft and doesn't impede the bone formation and osseointegration processes. Further clinical and histological studies are necessary to better define this amorphous tissue and an efficient and safe operative protocol in the surgery of bone with an Er:YAG laser.


Articles with similar content:

Comparing the effect of preparation of the implant sites with piezosurgery and conventional drilling on the stability of implants at 5-months follow-up
Journal of Long-Term Effects of Medical Implants, Vol.28, 2018, issue 1
Mohsen Bidgoli, Ehsan Houshyar, Maryam Farhadian, Ali Ghamari, Sara Soheilifar
Crestal Sinus Floor Elevation with Autogenous Press-Fit Dowel Bone Harvested Using Trephine Drills: A New Method
Journal of Long-Term Effects of Medical Implants, Vol.28, 2018, issue 3
Maryam Hossein Nezhad, Hamid Reza Arab, Amir Moeintaghavi, Farid Shiezadeh
Histologic and Histomorphometric Analysis of an Immediately Loaded Implant Retrieved from Man after 14 Months of Loading
Journal of Long-Term Effects of Medical Implants, Vol.15, 2005, issue 5
Giovanna Iezzi, Antonio Scarano, Marco Degidi, Adriano Piattelli
Effect of Bioactive Ceramic and Recombinant Human Transforming Growth Factor-Beta (rhTGF-beta) on Regeneration of Parietal Bone Defects in Rat
Journal of Long-Term Effects of Medical Implants, Vol.21, 2011, issue 1
Fariborz Nasseri, Mahdi Kadkhodazadeh, Gholam Ali Gholami
Designing Suitable Sizes of Hip Implants for Indian Patients
Journal of Long-Term Effects of Medical Implants, Vol.17, 2007, issue 4
Partha Sarathi Banerjee, Palash Kumar Maji, Anupam Sinha