ライブラリ登録: Guest
Begell Digital Portal Begellデジタルライブラリー 電子書籍 ジャーナル 参考文献と会報 リサーチ集
Journal of Long-Term Effects of Medical Implants
SJR: 0.145 SNIP: 0.491 CiteScore™: 0.89

ISSN 印刷: 1050-6934
ISSN オンライン: 1940-4379

Journal of Long-Term Effects of Medical Implants

DOI: 10.1615/JLongTermEffMedImplants.v17.i3.60
pages 229-236

Segmental Kinematics and Adjacent Level Degeneration Following Disc Replacement versus Fusion: RCT with Three Years of Follow-Up

Abdullah Nabhan
Department of Neurosurgery, Neurosurgical Department, University of Saarland, Homburg, Germany
W. I. Steudel
Department of Neurosurgery, Neurosurgical Department, University of Saarland, Homburg, Germany
Ah. Nabhan
Department of Orthopedics, Neurosurgical Department, University of Saarland, Homburg, Germany
D. Pape
Department of Orthopedics, Neurosurgical Department, University of Saarland, Homburg, Germany
B. Ishak
Department of Neurosurgery, Neurosurgical Department, University of Saarland, Homburg, Germany

要約

Study Design: Prospective, randomized and controlled clinical and radiological study. Objective: The aim of this study was to assess the segmental kinematics and clinical outcome of disc replacement with ProDisc C versus anterior cervical discectomy and fusion (ACDF) for monosegmental disease 3 years after surgery. Summary of Background Data: Anterior cervical discectomy and fusion (ACDF), including plate fixation, is an accepted technique for treatment of symptomatic degenerative disc disease (DDD). However, various studies could show that fusion of a relative mobile spinal segment leads to heightens of stresses on the discs below and above fusion, which is manifested as adjacent level degeneration. Intervertebral disc replacement has been attempted to restore intervertebral disc height and to maintain segmental motion, which may be thought to avoid the accelerated degeneration to the adjacent level. In earlier studies, we could show that ProDisc C could maintain segmental motion for 1 year after surgery. Methods: 49 patients with cervical disc herniation underwent arthroplasty of a single level using Pro−Disc C disc prosthesis or received fusion using a cage and anterior titanium plate fixation. Clinical outcome was assessed using the visual analogue scale (VAS) and the neck disability index (NDI). Radiostereometry was performed immediately postoperative and then after 1, 2, and 3 years after surgery to quantify the segmental kinematics. Results: The range of motion of the treated segment with prosthesis remained unchanged 3 years after surgery in comparison to the 1−year result. The prosthesis shows a significant segmental motion in contrast to the fusion group at each RSA examination time (p < 0.05). After both procedures, a significant pain reduction in neck and arm was observed, without significant differences between both groups. During the course of the 3 years follow-up, no patients of the prosthesis group required further surgical intervention.


Articles with similar content:

Analysis of Spinal Kinematics Following Implantation of Lumbar Spine Disc Prostheses versus Fusion: Radiological Study
Journal of Long-Term Effects of Medical Implants, Vol.17, 2007, issue 3
B. Ishak, O. Kollmar, O. Steimer, W. I. Steudel, A. Al-Yhary, Abdullah Nabhan
Clinical Application of Artificial Ligament for Ankle Instability—Long-Term Follow-Up
Journal of Long-Term Effects of Medical Implants, Vol.10, 2000, issue 4
Eiichi Hiraishi, Akeo Waseda, Norio Usami, Suguru Inokuchi, Masaki Miyanaga
Do Prior Intra-Articular Corticosteroid Injections or Time of Administration Increase the Risks of Subsequent Periprosthetic Joint Infections after Total Knee Arthroplasty?
Journal of Long-Term Effects of Medical Implants, Vol.26, 2016, issue 3
Samik Banerjee, Guneet S. Sodhi, Harpal S. Khanuja, Michael A. Mont
Excellent Early Outcomes of the First 100 Cruciate-Retaining TriathlonTM Total Knee Arthroplasties
Journal of Long-Term Effects of Medical Implants, Vol.23, 2013, issue 1
Robert Pivec, Mark J. McElroy, Swetha Dhanireddy, Michael A. Mont, Qais Naziri, Kimona Issa, Aaron J. Johnson
Implant Fracture after Long-Stemmed Cemented Hemiarthroplasty for Oncologic Indications
Journal of Long-Term Effects of Medical Implants, Vol.25, 2015, issue 3
Jenna Noveau, Robert Pivec, Aditya V. Maheshwari, Robert M. Henshaw, Corey Gilbert