ライブラリ登録: Guest
Begell Digital Portal Begellデジタルライブラリー 電子書籍 ジャーナル 参考文献と会報 リサーチ集
Heat Transfer Research
インパクトファクター: 0.404 5年インパクトファクター: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN 印刷: 1064-2285
ISSN オンライン: 2162-6561

巻:
巻 50, 2019 巻 49, 2018 巻 48, 2017 巻 47, 2016 巻 46, 2015 巻 45, 2014 巻 44, 2013 巻 43, 2012 巻 42, 2011 巻 41, 2010 巻 40, 2009 巻 39, 2008 巻 38, 2007 巻 37, 2006 巻 36, 2005 巻 35, 2004 巻 34, 2003 巻 33, 2002 巻 32, 2001 巻 31, 2000 巻 30, 1999 巻 29, 1998 巻 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2016010960
pages 669-680

EFFECT OF INLET WINDOWS DEFLECTORS AND WINDBREAK WALLS HEIGHT ON THE PERFORMANCE OF NATURAL DRAFT COOLING TOWER UNDER CROSSWIND CONDITIONS

Mohammad Mehdi Hemmasian Kashani
Department of Mechanical Engineering, Jasb Branch, Islamic Azad University, Jasb, Iran
K. V. Dobrego
A.V. Luikov Heat and Mass Transfer Institute, National Academy of Sciences of Belarus, Minsk, 220072, Belarus

要約

The environmental crosswind brings changes in the aerodynamic pattern inside and outside a cooling tower, destroys uniform flow, and may deteriorate the fill zone performance. The effect of inlet windows deflectors and windbreak walls on the performance of a natural draft cooling tower is studied by means of three-dimensional numerical modeling. An assumption of heat and mass transfer equivalence is adopted. The numerical model is tested and verified by experimental data. Nonlinear behavior of the functional dependence of performance on the crosswind velocity is demonstrated by the minimal (critical) wind velocity Ucr ~ 6.5 m/s. Utilization of the inlet window deflectors and windbreak walls do not change the value of the critical wind velocity, but may improve the performance of a natural draft cooling tower under moderate and strong wind conditions. Utilization of deflectors in the inlet windows increases the thermal efficiency of a cooling tower up to 8.6% at U > 2 m/s and has no effect at wind velocities close to Ucr. Utilization of windbreak walls of optimum height may increase the cooling tower efficiency up to 20−30%. It is demonstrated that the parameters of the vertical wind distribution influence the value of the critical wind velocity. The results of the work may be useful for optimal design of natural draft and "hybrid" cooling towers.


Articles with similar content:

INVESTIGATION OF THE ABSORPTION−COMPRESSION HYBRID REFRIGERATION APPLIED TO THE COACH AIR CONDITIONING
Heat Transfer Research, Vol.46, 2015, issue 3
Jianbo Li, Shaokang Kong, Shiming Xu
FIELD TEST ON THE COOLING PERFORMANCE FOR HIGH LEVEL WATER COLLECTING WET COOLING TOWER UNDER CROSSWIND CONDITIONS
International Heat Transfer Conference 16, Vol.9, 2018, issue
Fengzhong Sun, Zhigang Dang, Ming Gao, Jian Zou, Yang Zhou
ANALYSES OF MOTION AND DRAG COEFFICIENT OF WATER DROPLETS IN A NATURAL DRAUGHT COOLING TOWER
Proceedings of Symposium on Energy Engineering in the 21st Century (SEE2000) Volume I-IV, Vol.0, 2000, issue
Baomin Liu , M. N. A. Hawlader
Study of the Flow and Heat Transfer of Water Film on Hot Air Anti-Icing Airfoil Surface
International Heat Transfer Conference 15, Vol.46, 2014, issue
Jianjun Zhu, Wei Dong, Mei Zheng, Guilin Lei
IMPACT ANALYSIS OF VEHICLE CHASSIS MADE OF POLYMER METAL HYBRIDS
Composites: Mechanics, Computations, Applications: An International Journal, Vol.6, 2015, issue 4
Vimal Anand, A. Gautham Shankar, Varun Mathur, Gopalan Venkatachalam