ライブラリ登録: Guest
Begell Digital Portal Begellデジタルライブラリー 電子書籍 ジャーナル 参考文献と会報 リサーチ集
Journal of Enhanced Heat Transfer
インパクトファクター: 0.562 5年インパクトファクター: 0.605 SJR: 0.175 SNIP: 0.361 CiteScore™: 0.33

ISSN 印刷: 1065-5131
ISSN オンライン: 1026-5511

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.2015015645
pages 121-145

A CASE STUDY OF USING ENHANCED INTERCONNECT CHANNEL GEOMETRIES ON HEAT AND MASS TRANSFER CHARACTERISTICS OF ANODE-SUPPORTED PLANAR SOFC

Yogesh N. Magar
Thermal-Fluids & Thermal Processing Laboratory, Department of Mechanical and Materials Engineering, University of Cincinnati, Cincinnati, OH 45221-0072
Raj M. Manglik
Thermal-Fluids and Thermal Processing Laboratory, Mechanical and Materials Engineering, University of Cincinnati, 2600 Clifton Ave, Cincinnati, OH 45220, USA

要約

The role of enhanced heat transfer inside interconnect channels for improved convective cooling and thermal management of planar solid oxide fuel cells (SOFCs) is investigated. A case study of two different geometries (sinusoidal wavy or corrugated walls and offset-and- interrupted walls) is presented for a uniform electrochemical reaction rate with constant flow of moist hydrogen and air. The coupled heat and mass transfer is modeled by three-dimensional, steady-state equations for mass, momentum, energy, species transfer, and electrochemical kinetics, in which the porous-layer flow is in thermal equilibrium with the solid matrix and is coupled with the electrochemical reaction rate. The heat and mass transfer rates through the interconnect ducts as well as the electrodes on both the anode and cathode sides are computationally obtained. The temperature field and species mass distributions, along with variations in the friction factor and heat transfer coefficients describe the performance of the two flow-channel geometries. The relative thermal and hydrodynamic behavior is compared with that in plain rectangular-duct interconnects to evaluate their convective-cooling performance. The results demonstrate that the offset interrupted-wall geometry yields better cooling of the SOFC module.


Articles with similar content:

EFFECT OF OPERATING CONDITIONS ON PERFORMANCE OF A PROTON EXCHANGE MEMBRANE FUEL CELL (PEMFC)
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2012, issue
Ziari Yasmina Kerboua , Youcef Kerkoub , Ahmed Benzaoui
THREE-DIMENSIONAL COMPUTATIONAL MODEL OF TRANSPORT PHENOMENA IN A COMPLETE PEM FUEL CELL
HYSYDAYS
1st World Congress of Young Scientists on Hydrogen Energy Systems, Vol.0, 2005, issue
Ilaria Rosso, Andrea Musso, Luca Mercante, Giuseppe Gianolio
ANALYSIS OF THE CATHODE FLOODING IN A PROTON EXCHANGE MEMBRANE FUEL
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2009, issue
Mustapha Najjari, Faycel Khemili, Sassi Ben Nasrallah
Numerical Investigation of Fluid Flow and Heat Transfer in Periodic Porous Lattice-Flame Materials
International Heat Transfer Conference 15, Vol.40, 2014, issue
Suresh V. Garimella, Justin A. Weibel, Karthik K. Bodla, Swaminathan G. Krishnan
TRANSIENT PERFORMANCE OF COOLING FINS SUBJECT TO STEP INITIAL CONDITIONS
International Heat Transfer Conference 10, Vol.15, 1994, issue
Haim Kalman , E. Assis