年間 8 号発行
ISSN 印刷: 1065-5131
ISSN オンライン: 1563-5074
Indexed in
BOILING HEAT TRANSFER FROM A SILICON CHIP IMMERSED IN DEGASSED AND GAS-DISSOLVED FC-72: EFFECTED BY SIZE AND NUMBER DENSITY OF MICRO-REENTRANT CAVITIES
要約
Boiling heat transfer of FC-72 from newly developed treated surfaces with micro-reentrant cavities was studied experimentally. The surface structure was fabricated on a silicon chip by use of microelectronic fabrication techniques. Four kinds of treated surfaces with the combinations of two cavity mouth diameters (about 1.6 μm and 3.1 μm) and two number densities of the micro-reentrant cavities (81 l/cm2 and 96 × 103 l/cm2) were tested along with a smooth surface. Experiments were conducted at the liquid subcoolings of 3 K and 25 K with degassed and gas-dissolved FC-72. While the wall superheat at boiling incipience was strongly dependent on the dissolved gas content; it was little affected by the cavity mouth diameter and the liquid subcooling. The heat transfer performance of the treated surface was considerably higher than that of the smooth surface. The highest performance was obtained with a treated surface with a larger cavity mouth diameter and a larger cavity number density. The results were compared with those for previously developed treated surfaces.