MEASUREMENT OF ENTRAINED FRACTION NEAR ONSET OF ANNULAR TWO-PHASE FLOW IN BOILING SYSTEMS

巻 30, 発行 4, 2018, pp. 319-331
DOI: 10.1615/MultScienTechn.2018027071
Get accessGet access

要約

Predictions of annular two-phase flow using the mechanistic model are of interest to the nuclear industry as they present a viable means to predict dryout conditions with reasonable accuracy in untested fuel bundle geometries or operating conditions. Among many closures required for solution of the mechanistic model, an important initial value is the initial entrainment fraction (IEF). IEF refers to the fraction of liquid which is in the form of droplets at the transition to annular flow in a heated channel. While IEF prediction models and correlations are available in literature, these have not been validated as there are no data in literature which explicitly mention obtaining IEF. This paper reports measurements of entrained fraction made very near to the transition to annular flow. This provides us with a very good experimental estimate of IEF. Additionally, these results give important insights into the factors that govern IEF and highlight the influence of the churn flow regime and possibly heat flux on IEF.

によって引用された
  1. Walker SP, Dasgupta A, Phenomenological modelling of film-dryout ‘critical heat flux’, Nuclear Engineering and Design, 354, 2019. Crossref

  2. Zhu Qingzi, Wang Guanyi, Schlegel Joshua P., Yan Yikuan, Yang Xiaohong, Liu Yang, Ishii Mamoru, Buchanan John R., Experimental study of two-phase flow structure in churn-turbulent to annular flows, Experimental Thermal and Fluid Science, 129, 2021. Crossref

Begell Digital Portal Begellデジタルライブラリー 電子書籍 ジャーナル 参考文献と会報 リサーチ集 価格及び購読のポリシー Begell House 連絡先 Language English 中文 Русский Português German French Spain