ライブラリ登録: Guest
Begell Digital Portal Begellデジタルライブラリー 電子書籍 ジャーナル 参考文献と会報 リサーチ集
Interfacial Phenomena and Heat Transfer
ESCI SJR: 0.146

ISSN 印刷: 2169-2785
ISSN オンライン: 2167-857X

Open Access

Interfacial Phenomena and Heat Transfer

DOI: 10.1615/InterfacPhenomHeatTransfer.2015012028
pages 343-361

TWO-PHASE FLOW OF R245FA IN A 1MM CORRUGATION DEPTH PLATE HEAT EXCHANGER − PART II: FLOW BOILING HEAT TRANSFER

Farzad Vakili-Farahani
Laboratory of Heat and Mass Transfer, LTCM, Ecole Polytechnique Fédérale de Lausanne, Station 9, CH-1015 Lausanne, Switzerland; Swiss Federal Laboratories for Materials Science and Technology (Empa)
R. L. Amalfi
Laboratory of Heat and Mass Transfer, LTCM, Ecole Polytechnique Fédérale de Lausanne, Station 9, CH-1015 Lausanne, Switzerland
John R. Thome
Laboratory of Heat and Mass Transfer (LTCM), Ecole Polytechnique Fédérale de Lausanne (EPFL), Station 9, CH-1015 Lausanne, Switzerland

要約

This article is the second in a two-part study on two-phase flow of R245fa in a new promising and more compact plate heat exchanger (PHE). Two-phase adiabatic frictional pressure drops were detailed in Part I, while the flow boiling heat transfer coefficients were obtained and the results presented here in Part II. Upward flow boiling heat transfer was investigated locally within the PHE prototype using an IR camera to measure the local PHE wall temperatures with high resolution. A new experimental approach for PHEs was introduced in order to reduce the data and obtain the local pixel-by-pixel flow boiling heat transfer coefficients throughout the PHE. The influences of heat flux, mass flux, saturation temperature, vapor quality, and inlet condition on flow boiling heat transfer coefficients were obtainable. During the tests, the vapor qualities changed from 0 to 0.78 for mass fluxes from 7.5 to 40 kg m−2 s−1, heat fluxes from 250 to 3700 W m−2, and saturation temperatures from 19°C to 35°C. In addition, comparative flow boiling experiments were carried out with a small subcooling and then repeated with liquid-vapor (xin ~ 0.1−0.2) flow at the PHE inlet. Several of the most widely used prediction methods in the PHE literature were evaluated with respect to the current mean and quasi-local (obtained in six windows) experimental databases. The prediction methods mostly showed a better agreement with the mean flow boiling heat transfer coefficients rather than the local database.


Articles with similar content:

TWO-PHASE FLOW AND BOILING OF R245FA IN A 1 MM PRESSING DEPTH PLATE HEAT EXCHANGER − PART I: ADIABATIC PRESSURE DROP
Interfacial Phenomena and Heat Transfer, Vol.2, 2014, issue 4
R. L. Amalfi, John R. Thome, Farzad Vakili-Farahani
A REVIEW ON HEAT TRANSFER AND PRESSURE DROP DURING EVAPORATION AND CONDENSATION OF R22 INSIDE 9.52-MM O.D. MICROFIN TUBES OF DIFFERENT GEOMETRIES
Journal of Enhanced Heat Transfer, Vol.24, 2017, issue 1-6
Alfonso Niro, S. Arosio, Adriano Muzzio
Heat Transfer and Pressure Drop During Evaporation and Condensation of R22 inside 9.52-mm O.D. Microfin Tubes of Different Geometries
Journal of Enhanced Heat Transfer, Vol.5, 1998, issue 1
Alfonso Niro, S. Arosio, Adriano Muzzio
HEAT TRANSFER AND PRESSURE DROP DURING EVAPORATION AND CONDENSATION OF R134a INSIDE TWO MICROFIN TUBES OF NEW DESIGN
International Heat Transfer Conference 13, Vol.0, 2006, issue
Alfonso Niro, Andrea Lucchini, Luigi Pietro Maria Colombo, Adriano Muzzio
AN INVESTIGATION ON DIABATIC FLOW PATTERN CHARACTERISTICS DURING CONVECTIVE CONDENSATION INSIDE HORIZONTAL TUBES
4th Thermal and Fluids Engineering Conference, Vol.18, 2019, issue
Tiago A. Moreira, Gherhardt Ribatski