RT Journal Article ID 2f88fff36505ac98 A1 Hu, M. H. T1 A Bayesian Analysis of Steam Generator Tube Wall Emissivity for Heat Treatment JF International Journal of Fluid Mechanics Research JO FMR YR 1998 FD 1998-06-01 VO 25 IS 1-3 SP 351 OP 362 AB This paper develops a probabilistic method for estimating tube wall emissivity of a steam generator. Bayes' theorem combines the generic probability density function (pdf) of tube wall emissivity with specific data. The combination results in a specific pdf of the emissivity for specific steam generator. Estimates of the emissivity provide inputs for probabilistic estimation of tube wall temperature during field heat treatment of steam generator tubes. PB Begell House LK https://www.dl.begellhouse.com/journals/71cb29ca5b40f8f8,6b7c8043191c60e1,2f88fff36505ac98.html