Inscrição na biblioteca: Guest
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa
Journal of Long-Term Effects of Medical Implants
SJR: 0.133 SNIP: 0.491 CiteScore™: 0.89

ISSN Imprimir: 1050-6934
ISSN On-line: 1940-4379

Journal of Long-Term Effects of Medical Implants

DOI: 10.1615/JLongTermEffMedImplants.v13.i2.40
6 pages

Creating Another Barrier to the Transmission of Bloodborne Operative Infections with a New Glove Gauntlet

Richard Edlich
Legacy Verified Level I Shock Trauma Center Pediatrics and Adults, Legacy Emanual Hospital; and Plastic Surgery, Biomedical Engineering and Emergency Medicine, University of Virginia Health System, USA
Lisa G. Hill
Plastic Surgery Research Program, University of Virginia Health System, Charlottesville, Virginia
Tyler C. Wind
Plastic Surgical Research Program, University of Virginia Health System, Charlottesville, Virginia
John G. Thacker
Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, Virginia

RESUMO

While disposable surgical gowns are designed to be either liquid-resistant or liquid-proof apparel, the woven cuffs of surgical gowns are easily permeable to water, an invitation to the transmission of bloodborne infections. Regent Medical has redesigned the diameter of some of its surgical glove gauntlets to enhance the security of the glove/surgical cuff interface. The purpose of this biomechanical performance study was to evaluate the benefit of a narrow glove gauntlet in enhancing the security of the gown and cuff interface. Using three types of disposable gown, the narrow glove gauntlet significantly increased the security of the gown-glove interface. On the basis of this biomechanical performance study, Regent Medical has announced that it will be using this narrow glove gauntlet design on more of their glove products to further reduce the transmission of bloodborne operative infections.


Articles with similar content:

Wound Closure Sutures and Needles: A New Perspective
Journal of Environmental Pathology, Toxicology and Oncology, Vol.29, 2010, issue 4
Jill J. Dahlstrom, William B. Long III, Richard Edlich, Jamie J. Clark, Anne G. Wallis, K. Dean Gubler
An Update on the Innovative Surgical Double-Glove Hole Puncture Indication Systems: Reliability and Performance
Journal of Long-Term Effects of Medical Implants, Vol.27, 2017, issue 2-4
Tyler C. Wind, John G. Thacker, Richard Edlich, Cynthia L. Heather
Reliability and Performance of Innovative Surgical Double-Glove Hole Puncture Indication Systems
Journal of Long-Term Effects of Medical Implants, Vol.13, 2003, issue 2
Tyler C. Wind, John G. Thacker, Richard Edlich, Cynthia L. Heather
An Innovative Surgical Suture and Needle Evaluation and Selection Program
Journal of Long-Term Effects of Medical Implants, Vol.12, 2002, issue 4
John G. Thacker, George T. Rodeheaver, Richard Edlich, Robin R. Szarmach, Jean Livingston
A Review on the Innovative Surgical Suture and Needle Evaluation and Selection Program
Journal of Long-Term Effects of Medical Implants, Vol.27, 2017, issue 2-4
John G. Thacker, George T. Rodeheaver, Richard Edlich, Robin R. Szarmach, Jean Livingston