Inscrição na biblioteca: Guest
Journal of Long-Term Effects of Medical Implants

Publicou 4 edições por ano

ISSN Imprimir: 1050-6934

ISSN On-line: 1940-4379

SJR: 0.184 SNIP: 0.485 CiteScore™:: 1.1 H-Index: 39

Indexed in

Measurements of Surface and Subsurface Damage in Retrieved Polyethylene Tibial Inserts of a Contemporary Design

Volume 22, Edição 1, 2012, pp. 21-31
DOI: 10.1615/JLongTermEffMedImplants.v22.i1.40
Get accessGet access

RESUMO

In the present study, surface and subsurface damage due to wear and creep in retrieved tibial inserts from the Genesis II total knee replacement (Smith & Nephew, Memphis, TN) are quantified. The utility of a number of recently validated micro-computed tomography (micro-CT) techniques for use in retrieval studies are also demonstrated. Sixteen inserts retrieved from patients after an implantation time from 0.5 to 86 months were examined. The inserts were scanned using micro-CT, and the three-dimensional surface deviations (corresponding to wear and creep) between the retrieved inserts and a reference geometry were determined. The subsurface of the inserts was also examined. Deviations within damage features were measured, and a surface deviation rate (mm/ year) was calculated from the length of implantation. No subsurface fatigue damage was found. The mean deviation within the most damaged regions of the articular surface was 0.115 ± 0.064 mm medially and 0.099 ± 0.061 mm laterally (p = 0.20). The mean articular deviation rate for inserts in vivo for more than 1 year was 0.049 mm/year and was reduced to 0.026 mm/year in inserts implanted for more than 4 years. Wear and creep of the Genesis II PE insert was comparable to reported values in other total knee replacements.

CITADO POR
  1. Teeter Matthew G, Seslija Petar, Milner Jaques S, Nikolov Hristo N, Yuan Xunhua, Naudie Douglas D R, Holdsworth David W, Quantification ofin vivoimplant wear in total knee replacement from dynamic single plane radiography, Physics in Medicine and Biology, 58, 9, 2013. Crossref

  2. Teeter Matthew G., Parikh Amit, Taylor Marc, Sprague Jeff, Naudie Douglas D., Wear and Creep Behavior of Total Knee Implants Undergoing Wear Testing, The Journal of Arthroplasty, 30, 1, 2015. Crossref

  3. Gascoyne Trevor C., Teeter Matthew G., Guenther Leah E., Burnell Colin D., Bohm Eric R., Naudie Douglas R., In Vivo Wear Performance of Cobalt-Chromium Versus Oxidized Zirconium Femoral Total Knee Replacements, The Journal of Arthroplasty, 31, 1, 2016. Crossref

  4. Teeter Matthew G., Wihlidal Jacob, McCalden Richard W., Yuan Xunhua, MacDonald Steven J., Lanting Brent A., Naudie Douglas D., Radiostereometric Analysis Permits In Vivo Measurement of Very Small Levels of Wear in TKA, Clinical Orthopaedics & Related Research, 477, 1, 2019. Crossref

  5. Day Judd S., Abboud Joseph A., Implant Retrieval, in Reverse Shoulder Arthroplasty, 2016. Crossref

  6. Anderson F. L., Koch C. N., Elpers M. E., Wright T. M., Haas S. B., Heyse T. J., Oxidised zirconium versus cobalt alloy bearing surfaces in total knee arthroplasty, The Bone & Joint Journal, 99-B, 6, 2017. Crossref

  7. Teeter M. G., Thoren J., Yuan X., McCalden R. W., MacDonald S. J., Lanting B. A., Naudie D. D. R., Migration of a cemented fixed-bearing, polished titanium tibial baseplate (Genesis II) at ten years, The Bone & Joint Journal, 98-B, 5, 2016. Crossref

942 Visualizações do artigo 41 downloads de artigos Métricas
942 VISUALIZAÇÕES 41 TRANSFERÊNCIAS 7 Crossref CITAÇÕES Google
Scholar
CITAÇÕES

Artigos com conteúdo semelhante:

Ramus Frame Dental Implant Functional Survival and Safety in Severely Atrophic Edentulous Human Mandibles Journal of Long-Term Effects of Medical Implants, Vol.34, 2024, issue 3
O. Hilt Tatum Jr., Thomas E. Rams
Prospective Evaluation of Bone Remodeling in Full-Arch Rehabilitations with Morse Taper Implants: A Case Series Study with One-Year Follow-Up Journal of Long-Term Effects of Medical Implants, Vol.32, 2022, issue 3
Carolina Accorsi Cartelli, Sergio Rocha Bernardes, Larissa Carvalho Trojan, Marcos Boaventura de Moura, Geninho Thomé, Ángel José Sánchez Reyes
Morphological Variations of the Posterior Mandible: Proposing a Classification for Ridge Morphology Based on Cone-Beam Computed Tomography Data Journal of Long-Term Effects of Medical Implants, Vol.32, 2022, issue 2
Yaser Safi, Reza Amid, Maryam Alizad-Rahvar, Hamed Mortazavi
Practice-Based Clinical Evaluation of Dental Implants Placed with Immediate or Delayed Loading Protocols: One-Year Follow-Up Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 2
Leonardo Rigoldi Bonjardim, Ernesto Byron Benalcazar Jalkh, Paulo Guilherme Coelho, Adolfo Coelho de Oliveira Lopes, Karin Hermana Neppelenbroek, Estevam Augusto Bonfante, Abbas Zahoui, Paulo Sérgio Perri de Carvalho de Carvalho
Hydroxyapatite Enhances Long-Term Fixation of Titanium Implants Journal of Long-Term Effects of Medical Implants, Vol.16, 2006, issue 2
Mikael Sundfeldt, Olav Reikeras, Carina B. Johansson

Última edição

Design and Stability Analysis of an Adaptive Neuro-Fuzzy Inference System (ANFIS)−Based Pacemaker Controller in MATLAB Simulink Asghar Dabiri Aghdam, Nader Jafarnia Dabanloo, Fereidoun Nooshiravan Rahatabad, Keivan Maghooli Complications Following Intraosseous Injections of Calcium Phosphate Bone Cement in Subchondroplasty Christos B. Zachariadis, Helen C. Leligou, Stauros K. Kourkoulis, Evaggelos Magnisalis, Panayiotis J. Papagelopoulos, Olga D. Savvidou Complications Following Short Femoral Nail Fixation for Intertrochanteric Hip Fractures: A Retrospective Study Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, C. Nikakis, Stavros Angelis, Spyridon J. Maris, C. Grekas, Efthymios J. Karadimas, Alexandros P. Apostolopoulos Finite Element Analysis: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Ali Muhsin, Enas Kareem Mohammed, Khalid Bander C-Reactive Protein and Erythrocyte Sedimentation Rates after Total and Unicompartmental Knee Arthroplasty−Less Implant Equals Quicker Normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat Comparison of Roughness, Wettability, and SEM Features between Sandblasted Acid-Etched and Oxidized Titanium Dental Implants Kshitiz Chhabra, Arvina Rajasekar Correlation between Primary Stability of Dental Implants and Bone Density: A Retrospective Analysis S. Padmaja, Arvina Rajasekar

Próximos artigos

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa Políticas de preços e assinaturas Begell House Contato Language English 中文 Русский Português German French Spain