Inscrição na biblioteca: Guest
Journal of Long-Term Effects of Medical Implants

Publicou 4 edições por ano

ISSN Imprimir: 1050-6934

ISSN On-line: 1940-4379

SJR: 0.184 SNIP: 0.485 CiteScore™:: 1.1 H-Index: 39

Indexed in

Stress and Strain Distribution Patterns in Bone around Tissue- and Bone-Level Implant-Supported Mandibular Overdentures Using Three-Dimensional Finite-Element Analysis

Volume 29, Edição 3, 2019, pp. 175-181
DOI: 10.1615/JLongTermEffMedImplants.2019031747
Get accessGet access

RESUMO

Our aim is to investigate the effect of implant placement in two positions (bone level and tissue level) on stress and strain distribution around mandibular implant overdentures. We use two models of mandibular overdentures. Taper implants are inserted and collimated between the lateral and canine teeth. All structures are scanned, digitized, and three-dimensioned (3D) model designed. We apply a vertical load of 100 N simultaneously on the central fossa of the mandibular first molar of the two models (bone- and tissue-level implant). Stress and strain values are obtained using 3D finite-element analysis (FEA). In comparison to the tissue-level model, bone-level implants can reduce overdenture movement and tension by 0.8 μm. The results of this study show that using bone-level implants can reduce tension on the prosthesis part of the overdenture and the bone around the implants as well as on the movement of the distal end of the mandibular overdenture. We found that bone strain occurred around implants within physiological limits in model 1 (bone level) compared to model 2 (tissue level). This shows that the distribution of physical forces in bone-level implants generally produces better results than those of issue-level implants. However, more research on the subject is needed.

Referências
  1. John J, Rangarajan V, Savadi RC, Satheesh Kumar KS, Satheesh Kumar P. A finite element analysis of stress distribution in the bone, around the implant supporting a mandibular overdenture with ball/o ring and magnetic attachment. J Indian Prosthodont Soc. 2012;12(1):37-44. .

  2. Reddy PM, Thumati P. A 3D finite element analysis of strain around end osseous threaded and non-threaded implant-opposing natural teeth with regular occlusion and altered occlusion: an in vitro study. J Dent Implants. 2014;4(1):53. .

  3. Amid R, Kadkhodazadeh M, Dehnavi F, Brokhim M. Comparison of stress and strain distribution around splinted and non-splinted teeth with compromised periodontium: a three-dimensional finite element analysis. J Periodontal Implant Dent. 2018;10(1):35-41. .

  4. Omori M, Sato Y, Kitagawa N, Shimura Y, Ito M. A bio-mechanical investigation of mandibular molar implants: reproducibility and validity of a finite element analysis model. Int J Implant Dent. 2015;1(1):10. .

  5. Lindquist LW, Rockler B, Carlsson GE. Bone resorption around fixtures in edentulous patients treated with mandibular fixed tissue-integrated prostheses. J Prosthet Dent. 1988;59(1):59-63. .

  6. Ogawa T, Sato Y, Kitagawa N, Nakatsu M. Relationship between retention forces and stress at the distal border in maxillary complete dentures: measurement of retention forces and finite-element analysis in individual participants. J Prosthet Dent. 2017;117(4):524-531. .

  7. Barao VA, Delben JA, Lima J, Cabral T, Assuncao WG. Comparison of different designs of implant-retained overdentures and fixed full-arch implant-supported pros-thesis on stress distribution in edentulous mandible. A computed tomography-based three-dimensional finite element analysis. J Biomech. 2013;46(7):1312-20. .

  8. Amid R, Rasoolzadeh RA, Motlagh AM, Dehnavi F, Kadkhodazadeh M. Stress and strain distribution patterns in bone around splinted standard and short implants placed at the crestal level and subcrestally using three-dimensional finite element analysis. J Long Term Effects Med Implants. 2017;27(1):1-11. .

  9. Quirynen M, Naert I, Van Steenberghe D. Fixture design and overload influence marginal bone loss and future success in the Branemark system. Clin Oral Implants Res. 1992;3(3):104-11. .

  10. Batenburg RH, Raghoebar GM, Van Oort RP, Heijdenrijk K, Boering G. Mandibular overdentures supported by two or four endosteal implants: a prospective, comparative study. Int J Oral Maxillofac Surg. 1998;27(6):435-9. .

  11. Akca K, Akkocaoglu M, Comert A, Tekdemir I, Cehreli MC. Bone strains around immediately loaded implants supporting mandibular overdentures in human cadavers. Int J Oral Maxillofac Implants. 2007;22(1):101-9. .

  12. Daas M, Dubois G, Bonnet AS, Lipinski P, Rignon-Bret C. A complete finite element model of a mandibular implant-retained overdenture with two implants: comparison between rigid and resilient attachment configurations. Med Eng Phys. 2008;30(2):218-25. .

  13. Dashti MH, Atashrazm P, Emadi MI, Mishaeel S, Banava S. The effects of two attachment types on the stresses in-troduced to the mandibular residual ridge: a 3D finite element analysis. Quintes Int. 2013;44(8):585-90. .

  14. Arat Bilhan S, Baykasoglu C, Bilhan H, Kutay O, Mugan A. Effect of attachment types and number of implants sup-porting mandibular overdentures on stress distribution: a computed tomography-based 3D finite element analysis. J Biomech. 2015;48(1):130-7. .

  15. Vafaei F, Khoshhal M, Bayat-Movahed S, Ahangary AH, Firooz F, Izady A, Rakhshan V. Comparative stress distri-bution of implant-retained mandibular ball-supported and bar-supported overlay dentures: a finite element analysis. J Oral Implantol. 2011;37(4):421-9. .

  16. Assuncao WG, Tabata L, Barao VAR, Rocha EPJJ. Comparison of stress distribution between complete denture and implant-retained overdenture-2D FEA. J Oral Rehab. 2008;35(10):766-74. .

  17. Tabata LF, Assuncao WG, Barao VAR, Gomes EA, Delben JA, de Sousa EAC, Rocha EP. Comparison of single-standing or connected implants on stress distribution in bone of mandibular overdentures: a two-dimensional finite element analysis. J Craniofac Surg. 2010:21(3):696-702. .

  18. Barao VA, Delben JA, Lima J, Cabral T, Assuncao WG. Comparison of different designs of implant-retained overdentures and fixed full-arch implant-supported pros-thesis on stress distribution in edentulous mandible. A computed tomography-based three-dimensional finite element analysis. J Biomechan. 2013;46(7):1312-20. .

  19. Barao VAR, Assuncao WG, Tabata LF, Delben JA, Gomes EA, de Sousa EAC, Rocha EP. Finite element analysis to compare complete denture and implant-retained overdentures with different attachment systems. J Craniofac Surg. 2009;20(4):1066-71. .

  20. Frost HM. Bone "mass" and the "mechanostat": a proposal. Anat Rec. 1987;219(1):1-9. .

  21. Melsen B, Lang NP. Biological reactions of alveolar bone to orthodontic loading of oral implants. Clin Oral Implants Res. 2001;12(2):144-52. .

  22. Cehreli MC, Karasoy D, Kokat AM, Akca K, Eckert S. A systematic review of marginal bone loss around implants retaining or supporting overdentures. Int J Oral Maxillofac Implants. 2010;25(2):266-77. .

Última edição

Design and Stability Analysis of an Adaptive Neuro-Fuzzy Inference System (ANFIS)−Based Pacemaker Controller in MATLAB Simulink Asghar Dabiri Aghdam, Nader Jafarnia Dabanloo, Fereidoun Nooshiravan Rahatabad, Keivan Maghooli Complications Following Intraosseous Injections of Calcium Phosphate Bone Cement in Subchondroplasty Christos B. Zachariadis, Helen C. Leligou, Stauros K. Kourkoulis, Evaggelos Magnisalis, Panayiotis J. Papagelopoulos, Olga D. Savvidou Complications Following Short Femoral Nail Fixation for Intertrochanteric Hip Fractures: A Retrospective Study Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, C. Nikakis, Stavros Angelis, Spyridon J. Maris, C. Grekas, Efthymios J. Karadimas, Alexandros P. Apostolopoulos Finite Element Analysis: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Ali Muhsin, Enas Kareem Mohammed, Khalid Bander C-Reactive Protein and Erythrocyte Sedimentation Rates after Total and Unicompartmental Knee Arthroplasty−Less Implant Equals Quicker Normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat Comparison of Roughness, Wettability, and SEM Features between Sandblasted Acid-Etched and Oxidized Titanium Dental Implants Kshitiz Chhabra, Arvina Rajasekar Correlation between Primary Stability of Dental Implants and Bone Density: A Retrospective Analysis S. Padmaja, Arvina Rajasekar

Próximos artigos

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa Políticas de preços e assinaturas Begell House Contato Language English 中文 Русский Português German French Spain