pages 49-56

Regional Measurements of Surface Deviation Volume in Worn Polyethylene Joint Replacement Components

Matthew G Teeter
Division of Orthopaedic Surgery, London Health Sciences Centre, London, Ontario, N6A 5A5, Canada
Jaques S. Milner
Imaging Research Laboratories, Robarts Research Institute, London, Ontario
Jennifer L. Au
Imaging Research Laboratories, Robarts Research Institute, London, Ontario
Daniel Lorusso
Imaging Research Laboratories, Robarts Research Institute, London, Ontario
Douglas D. R. Naudie
Division of Orthopaedic Surgery, The University of Western Ontario, London, ON
David W. Holdsworth
Imaging Research Laboratories, Robarts Research Institute; Department of Medical Biophysics; Division of Orthopaedic Surgery, The University of Western Ontario

RESUMO

Total joint replacements can be subject to the loss of polyethylene material due to wear, leading to osteolysis and decreased implant longevity. Micro-computed tomography (micro-CT) techniques have recently been developed to calculate 3D surface deviations in worn implant components. We describe a micro-CT technique to measure the volume of the surface deviations (volume of wear plus creep) within a specific region or compartment, and report its repeatability and reproducibility. Six worn polyethylene tibial inserts were scanned using a laboratory micro-CT scanner and subsequently reconstructed at 50 μm voxel spacing. A previously developed custom software application was used to quantify the 3D surface deviations between the worn tibial inserts and an unworn reference geometry. Three observers (two trained and one expert) used new custom software to manually outline the localized regions of surface deviation (three times for each of the worn inserts) and calculate the volume of the deviations. The overall intrao- bserver variability in the surface deviation volumes was 3.6% medially and 1.1% laterally. The overall in- terobserver variability was 4.8% medially and 1.7% laterally. Placement of points in outlining the region of deviation contributed the greatest variability to the measurements. Repeatability and reproducibility of the volume measurements are similar to measurements of total (nonregional) wear volume including a previous micro-CT technique (10%), fluid displacement (4.8%), and radiographic measurements (15.7%). The principles of this technique can likely be used to measure regional wear and creep volume in knee and hip joint replacement components from wear simulator, pin-on-disk, and retrieval studies.


Articles with similar content:

Measurements of Surface and Subsurface Damage in Retrieved Polyethylene Tibial Inserts of a Contemporary Design
Journal of Long-Term Effects of Medical Implants, Vol.22, 2012, issue 1
Jan-M. Brandt, David W. Holdsworth, Matthew G Teeter, Eric R. Bohm, Douglas D. R. Naudie, Richard W. McCalden
Risk Factors Associated with Adjacent and Remote- Level Pathologic Vertebral Compression Fracture Following Balloon Kyphoplasty: 2-Year Follow-Up Comparison Versus Conservative Treatment
Journal of Long-Term Effects of Medical Implants, Vol.25, 2015, issue 4
Donald Hohman, Chetan Deshpande, Michael J. Faloon, Conor Dunn, Nicholas Beckloff, Mark Ruoff, Dipak V. Patel
APPLICATION OF IMAGE PROCESSING FOR FROST DENSITY PREDICTION
Journal of Flow Visualization and Image Processing, Vol.8, 2001, issue 4
Cheolhwan Kim, Jongmin Shin
Investigating the Morphology of the Proximal Femur of the Indian Population Towards Designing More Suitable THR Implants
Journal of Long-Term Effects of Medical Implants, Vol.22, 2012, issue 1
Debasis Datta, Amit Roychowdhury, Palash Kumar Maji
Pathological Hip Fractures in Children and Adolescents Due to Benign Tumor or Tumor-Like Lesions
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 2
Dimitrios Filippou, Stavros Angelis, John Ν.  Michelarakis, Elefterios Bogris, Petros Papapostolou, Georgios Vynichakis, Michail Chandrinos, Athanasios Kasiaras, Alexandros P. Apostolopoulos, Hristos Mirtsios