pages 185-192

A Comparison of the Compressive Strength of Various Distal Locking Screw Options in the Treatment of Tibia Fractures with Intramedullary Nails

Fred Xavier
Department of Orthopaedic Surgery & Rehabilitation Medicine, SUNY Downstate Medical Center, Brooklyn, New York 11203; Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021
E. Goldwyn
Department of Orthopaedic Surgery & Rehabilitation Medicine, SUNY Downstate Medical Center, Brooklyn, New York 11203
Westley T. Hayes
Department of Orthopaedic Surgery and Rehabilitation Medicine, SUNY Downstate Medical Center/University Hospital Brooklyn, Brooklyn, NY
A. Carrer
Department of Orthopaedic Surgery & Rehabilitation Medicine, SUNY Downstate Medical Center, Brooklyn, New York 11203
R. Elkhechen
Department of Orthopaedic Surgery & Rehabilitation Medicine, SUNY Downstate Medical Center, Brooklyn, New York 11203
M. Berdichevsky
Department of Orthopaedic Surgery & Rehabilitation Medicine, SUNY Downstate Medical Center, Brooklyn, New York 11203
A. Goldman
Department of Orthopaedic Surgery & Rehabilitation Medicine, SUNY Downstate Medical Center, Brooklyn, New York 11203
William P. Urban
Department of Orthopaedic Surgery and Rehabilitation Medicine, State University of New York (SUNY), Downstate Medical Center, Brooklyn, NY
Subrata Saha
University of Washington, Department of Restorative Dentistry Affiliated Faculty, Department of Oral & Maxillofacial Surgery School of Dentistry, University of Washington, Seattle, WA

RESUMO

Treatment of distal metaphyseal tibia fractures is often challenging. Newer tibial intramedullary (IM) nails are designed with a wider variety of distal locking options to offer greater stability in treating these fractures. In this study we attempted to determine the most biomechanically stable number and configuration of distal locking screws when treating distal metaphyseal tibia fractures with IM nails. A transverse osteotomy was created 4 cm from the tibial plafond in identical composite saw bones models (Type 43A fracture) as well as in human cadaveric bones. Each specimen was nailed using a tibial nail (Stryker T2). Distal locking was performed in one of the three configurations: (a) Group I: two screws in the medial lateral (ML) direction; (b) Group II: one ML screw and one screw in the anterior posterior (AP) direction; (c) Group 111: two ML screws and one AP screw. The specimens were then mounted onto a uniaxial material testing machine (Instron) and tested in compression. Our results showed that there was no statistical difference in the load-carrying capacity of Group 1 and Group II. This suggests that the treating surgeon can choose either of these two configurations depending on the wound or other considerations without sacrificing the compressive load-carrying capacity of the IM nail fixation. The load-carrying capacity of the Group III samples with these locking screws was higher than those of Group I & II, although this difference was not statistically significant. This work is being continued to compare the load-carrying capacity of the bone samples with the cortical thickness of bone. We also plan to examine the relationship between the load-carrying capacity of these surgical constructs with the bone mineral density of the metaphysis of these tibial specimens.


Articles with similar content:

Comparison of Stress Distribution in Alveolar Bone with Different Implant Diameters and Vertical Cantilever Length via the Finite Element Method
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 1
Mahsa Rashidpour, Paniz Fasihg, Niloufar Ahmadian, Ashraf Sayyedi, Mohammad Dehghan, Forouzan Faghani, Amir Fayyaz
Decreased Tibial Bone Strength in Postmenopausal Women with Aseptic Loosening of Cemented Femoral Implants Measured by Peripheral Quantitative Computed Tomography (pQCT)
Journal of Long-Term Effects of Medical Implants, Vol.21, 2011, issue 4
E. Papakitsou, I. Donta, Andreas Morakis, G. P. Lyritis, S. Tournis
Can Ultrastructural Particle Location Predict Aseptic Loosening? A Biopsy Study of Nonloose Hip Implants One Year Postoperative Using Three Bearing Material Combinations
Journal of Long-Term Effects of Medical Implants, Vol.17, 2007, issue 4
F. Elling, Marianne Nygaard, Kjeld Soballe, A. Borgwardt, L. Bastholm
Effectiveness of Negative-Pressure Wound Therapy following Total Hip and Knee Replacements
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 1
Videshnandan Raut, Hosam E. Matar, Nicholas Emms
EFFECTS OF CERVICAL DISC REPLACEMENT AND ANTERIOR FUSION FOR DIFFERENT BONE CONDITIONS: A FINITE ELEMENT STUDY
International Journal for Multiscale Computational Engineering, Vol.17, 2019, issue 4
Jayanta Kumar Biswas, Masud Rana, Rururaj Pradhan, Sandipan Roy, Sourav Majumdar