Volume 51, 2020 Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2012005913
pages 749-765

THE EFFECT OF AIR GAP THICKNESS ON HEAT TRANSFER IN FIREFIGHTERS' PROTECTIVE CLOTHING UNDER CONDITIONS OF SHORT EXPOSURE TO HEAT

Song He
State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, Anhui 230027, P. R. China
Dongmei Huang
State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, Anhui 230027, P. R. China
Zhengkun Qi
State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, Anhui 230027, P. R. China
Hui Yang
State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, Anhui 230027, P. R. China
Yin Hu
State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, Anhui 230027, P. R. China
Heping Zhang
State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, Anhui 230027, P. R. China

RESUMO

In this paper, the mechanism of heat transfer through the air gap between the layers of the fire protective clothing (FPC) and human skin under conditions of relatively short exposure to heat is studied. In the experiments, the thickness of the air gap varied from 0 mm to 10 mm with a step of 1 mm. The temperature on the simulated skin increased with the air gap until the thickness reached 7 mm. During a further increase from 8 mm to 10 mm, the temperature remained the same, and a little change could be observed. Corresponding to the experimental results, the Rayleigh number exceeded a value of 103 when the air-gap thickness was larger than 7 mm, and the convective heat transfer in the air gap cannot be ignored.


Articles with similar content:

Characterization of heat transfer fluctuation in a turbulent pipe flow with rectangular wave pulsation
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2018, issue
Shunsuke Yamada, Hajime Nakamura
A STUDY OF TRANSIENT EFFECTS LEADING UP TO INCEPTION OF NUCLEATE BOILING
International Heat Transfer Conference 6, Vol.1, 1978, issue
E. Oker, Herman Merte, Jr.
Solar PV Passive Temperature Control Using Phase Change Materials
International Heat Transfer Conference 15, Vol.49, 2014, issue
Pascal Henry Biwole, Dominic Groulx
Designing optimal heat transfer experiments − A case study
International Heat Transfer Conference 12, Vol.24, 2002, issue
L. van Belle, Ashley F. Emery
HEAT TRANSFER FROM SPHERES UP TO Re = 6 × 106
International Heat Transfer Conference 6, Vol.5, 1978, issue
Elmar Achenbach