Inscrição na biblioteca: Guest
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa
Heat Transfer Research
Fator do impacto: 0.404 FI de cinco anos: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimir: 1064-2285
ISSN On-line: 2162-6561

Volumes:
Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2013006189
pages 665-686

TRIPLE TUBE AMMONIA EVAPORATOR DESIGN FOR DOMESTIC ABSORPTION REFRIGERATORS

Ahmed Mohammed Adham
Erbil Polytechnic University
Normah Mohd-Ghazali
Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor Barhru, Malaysia
Mikdam M. Saleh
Power Engineering Department, College of Engineering, University of Baghdad, Al‐Jadriya, Baghdad, Iraq
Robiah Ahmad
UTM Razak School of Engineering and Advanced Technology, Universiti Teknologi Malaysia International campus, 54100 Jalan Semarak, Kuala Lumpur, Malaysia

RESUMO

A usable concept for an ammonia evaporator in an absorption refrigerator based on a triple tube design is considered. The differential equations that describe the energy transfer between the ammonia refrigerant and the ammonia hydrogen gas mixture are utilized to simulate the thermal and hydrodynamic performances and hence to determine the operation of evaporator. This simulation procedure is used to determine the geometrical parameters of the evaporator, subject to certain optimization criteria that were incorporated in a cost function. The final design of the evaporator, which is based on 100 W of cooling power at −6.7 °C, has a length of 1.523 m and triple tube diameters of 28.5, 22.2, and 15.8 mm. The evaporator's design is such that only a single penetration through the refrigerator's wall is necessary, which greatly simplifies the construction and reduces its cost.


Articles with similar content:

APPROXIMATION ASSISTED OPTIMIZATION OF PILLOW PLATE HEAT EXCHANGERS
International Heat Transfer Conference 16, Vol.14, 2018, issue
Radia Eldeeb, Vikrant Aute, Reinhard Radermacher, Jiazhen Ling
EXPERIMENTAL INVESTIGATION OF A REHEATING TWO-STAGE ADSORPTION CHILLER APPLYING FIXED CHILLED WATER OUTLET CONDITIONS
Heat Transfer Research, Vol.46, 2015, issue 3
Takahiko Miyazaki, Yuki Ueda, I Gusti Agung Bagus Wirajati, Atsushi Akisawa
ENERGY AND EXERGY ANALYSIS OF A DOUBLE STAGE HYBRID HEAT PUMP OPERATING WITH WATER AMMONIA
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2014, issue
Nahla Bouaziz, Ridha Ben Iffa, Dorra Lounissi
A NUMERICAL INVESTIGATION OF THERMALLY ACTIVATED GLASS FIBRE REINFORCED GYPSUM ROOF
Proceedings of the 24th National and 2nd International ISHMT-ASTFE Heat and Mass Transfer Conference (IHMTC-2017), Vol.0, 2017, issue
M. Prakash Maiya, S. M. S. Nagendra , K. Dharmasastha
Noise and Its Influence on Air Cooled Heat Exchanger Design
ICHMT DIGITAL LIBRARY ONLINE, Vol.19, 1981, issue
P. E. Farrant