Inscrição na biblioteca: Guest
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa
Heat Transfer Research
Fator do impacto: 0.404 FI de cinco anos: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimir: 1064-2285
ISSN On-line: 2162-6561

Volumes:
Volume 51, 2020 Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2012003418
pages 557-569

Thermal Plume in a Vertical Channel: Effect of the Source−Channel Vertical Spacing

Jouini Belgacem
LETTM, Faculte Sciences de Tunis Campus Universitaire, 1060 Tunis, TUNISIE
Mourad Bouterra
LETTM, Faculte Sciences de Tunis Campus Universitaire, 1060 Tunis, TUNISIE
Olivier Vauquelin
IUSTI, UMR CNRS 6595, Technopole de chateau Gombert,Marseille, FRANCE
Mohamed Afif El Cafsi
LETTM, Faculte Sciences de Tunis Campus Universitaire, 1060 Tunis, TUNISIE
Ali Belghith
Faculte des Sciences de Tunis, Laboratoire des Transferts de Chaleur et de Masse, Campus Universitaire, 1060 Tunis, Tunisia
Philippe Bornot
IUSTI, UMR CNRS 6595, Technopole de chateau Gombert,Marseille, FRANCE

RESUMO

This paper presents the results of a numerical study of the problem on turbulent convection in a vertical channel located above a rectangular heat source. The hot source is heated to a temperature Ts. The inner walls of the channel chain are heated (to a temperature Tp) following the issuance of thermal radiation from the hot source. In this study, we used the commercial software (CFD), Fluent, constructing an averaged standard κ−ε model. This software is based on the use of the finite volume method. The work involves a comparison between the numerical results with those of experience in literature. The comparison gives good agreement between the two results. We studied the effect of the source-channel spacing position by setting the source position relative to the channel in the vertical direction. We are also interested in the effect of the source-channel spacing of the recirculation zone formed above the heat source.


Articles with similar content:

Thermal Environmental Characteristics in Ondol Heated Space Considering Floor Heat Conduction
International Heat Transfer Conference 11, Vol.19, 1998, issue
Sun Sok Kwon, Hwataik Han, Yong II Kwon
PREFACE: INTERNATIONAL WORKSHOP ON HEAT TRANSFER ADVANCES FOR ENERGY CONSERVATION AND POLLUTION CONTROL (IWHT-2013) PART 2
Heat Transfer Research, Vol.47, 2016, issue 3
Zhixiong Guo, Bengt Sunden, Yitung Chen, Qiu-Wang Wang
Numerical Modeling of Compartment Fires
Heat Transfer Research, Vol.36, 2005, issue 7
A. P. Zykov, S. E. Yakush
NATURAL CONVECTION IN A RECTANGULAR ENCLOSURE WITH AN ARRAY OF DISCRETE HEAT SOURCES
Heat Transfer Research, Vol.48, 2017, issue 5
S. Saravanan, P. Kandaswamy, V. P. M. Senthil Nayaki
NON-DARCY BUOYANCY FLOW IN A SQUARE CAVITY FILLED WITH POROUS MEDIUM FOR VARIOUS TEMPERATURE DIFFERENCE ASPECT RATIOS
Journal of Porous Media, Vol.14, 2011, issue 7
Tanmay Basak, Satyajit Roy, M. Sathiyamoorthy