Inscrição na biblioteca: Guest
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa
Heat Transfer Research
Fator do impacto: 0.404 FI de cinco anos: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimir: 1064-2285
ISSN On-line: 2162-6561

Volumes:
Volume 51, 2020 Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2016013378
pages 781-795

EXPERIMENTAL STUDY OF HEAT TRANSFER CONTROL AROUND AN OBSTACLE BY USING A RIB

Zahra Ghorbani-Tari
Division of Heat Transfer, Department of Energy Sciences, Lund University, P.O. Box 118, SE-22100, Lund, Sweden
Bengt Sunden
Division of Heat Transfer, Department of Energy Sciences, Lund University, P.O. Box 118, SE-22100, Lund, Sweden

RESUMO

This paper investigates the effect of the presence of a rib on the end-wall heat transfer of an obstacle by liquid crystal thermography. An obstacle with a rectangular cross section is placed in a rectangular channel and blocks the entire height of it (AR = 4). A rib with a square cross section is placed at two positions, i.e., in the upstream and downstream areas of the obstacle, respectively. An important parameter in dealing with the control of heat transfer around an obstacle using a rib is the spacing between them. The spacing S, normalized by the spanwise width of the obstacle, has the values 1.25 and 0.625. The effect of the rib height, normalized by the channel hydraulic diameter, e/Dh, is also investigated by considering two values of it, i.e., 0.078 and 0.039, respectively. The results show that the local heat transfer especially in the upstream region of the obstacle is substantially modified by the upstream rib, e/Dh and S/d. The local heat transfer in the downstream region is more affected by the rib height, e/Dh. The local heat transfer in the upstream area of the obstacle is found nearly unaffected by the downstream rib regardless of the rib height e/Dh and S/d. It is found that the local heat transfer in the downstream area of the obstacle is modified differently and it is strongly affected by the rib height e/Dh and S/d. The heat transfer pattern due to the flow reattachment in the downstream area is significantly modified by the rib height e/Dh. The area influenced by the enhancement is found to be more affected by S/d. A larger enhancement area reflected a stronger impact associated with the heat transfer mechanism for e/Dh = 0.078.


Articles with similar content:

CHARACTERISTICS OF HEAT TRANSFER AROUND AN OBSTACLE CONTROLLED BY THE PRESENCE OF RIBS
Heat Transfer Research, Vol.47, 2016, issue 10
Lei Wang, Bengt Sunden, Zahra Ghorbani-Tari
STUDY ON FLOW AND HEAT TRANSFER MECHANISM OF CORRUGATED PLATE HEAT EXCHANGER
International Heat Transfer Conference 16, Vol.14, 2018, issue
Bingxi Li, Huaizhi Han, Qian Wang, Ruitian Yu
EXPERIMENTAL STUDY OF IMPINGING HEAT TRANSFER OF INLINE AND STAGGERED JET ARRAYS BY TRANSIENT LIQUID CRYSTAL TECHNIQUE
Journal of Flow Visualization and Image Processing, Vol.10, 2003, issue 1-2
H. C. Liu, W. M. Yan, Chyi-Yeou Soong
TRANSIENT LIQUID CRYSTAL TECHNIQUE FOR IMPINGING HEAT TRANSFER OF INLINE AND STAGGERED JET ARRAYS
Journal of Flow Visualization and Image Processing, Vol.24, 2017, issue 1-4
H. C. Liu, Wen-Jei Yang, W. M. Yan, Chyi-Yeou Soong
FLOW AND HEAT TRANSFER CHARACTERISTICS IN A CHANNEL OBSTRUCTED BY A SQUARE ROD MOUNTED IN ASYMMETRIC POSITIONS
Transport Phenomena in Thermal Engineering. Volume 2, Vol.0, 1993, issue
Kazuhisa Fukutani, Hiroshi Suzuki, Kenjiro Suzuki, Toshiyuki Takishita