Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2018025424
pages 17-32

EXPERIMENTAL INVESTIGATION OF THE EFFECT OF FLOW BLOCKAGES ON HEAT TRANSFER AND FLUID FRICTION IN A ROUND TUBE USING WALL-ATTACHED CIRCULAR RINGS

Adhikrao Patil
Research Scholar,Department of Mechanical Engineering, Sinhgad College of Engineering, Savitribai Phule Pune University, Pune
Sandeep S. Kore
Sinhgad Academy of Engineering, Pune, India, 411048 Savitribai Phule Pune University, Pune, India
Narayan K. Sane
Department of Mechanical Engineering Walchand College of Engineering Vishrambag, SANGLI - 416 415 (Maharashtra), INDIA

RESUMO

This paper studies the flow blockage effect on thermal performance in a round tube. The experiments were carried on a heat exchanging tube which is fitted with wall-attached circular rings (with no gap between the ring and inner wall of the tube) as a flow blockage device. The aim of this investigation is to introduce a flow blockage area (FBA) as a new parameter to evaluate the performance of different turbulators (turbulator is a passive device which induces secondary/reverse flow within the flow field). The wall-attached circular rings were selected as flow blockage geometry and configured with different inner diameters to achieve flow blockage area of 30%, 40%, and 50%. The parameters varied during the tests were FBA, the pitch-to-diameter ratio (PDR), and the Reynolds number. Air with ambient temperature was used as a working fluid in a test tube in which the inner wall is maintained at a uniform heat flux. The Reynolds number and pitch-to-diameter ratio were varied from 6000 to 24,000 and from 2 to 4, respectively. Significant enhancement in heat transfer rate up to 3.04 times that of the smooth tube was observed with inserts of 50% FBA and a smaller pitch-to-diameter ratio, i.e., 2 at a higher Reynolds number. An insert, i.e., a circular ring which offers flow blockage area of 30% and pitch-to-diameter ratio 2, gives the highest overall performance factor (1.26) at a lower Reynolds number.


Articles with similar content:

EXPERIMENTAL INVESTIGATION ON HEAT TRANSFER AUGMENTATION IN HORIZONTAL TUBE USING COILED WIRE INSERTS
Journal of Enhanced Heat Transfer, Vol.26, 2019, issue 5
Madhu Sruthi Emani, Sujoy Kumar Saha, Abhik Nayak, Achin Kumar Chowdhuri, Bijan Kumar Mandal
THE IMPROVEMENT OF THERMAL PERFORMANCES OF TUBULAR HEAT EXCHANGERS BY USING WIRE-COIL INSERTS
ICHMT DIGITAL LIBRARY ONLINE, Vol.1, 2000, issue
Bogosav Vasijevic, Rade Milenkovic
Abstacr of "THE IMPROVEMENT OF THERMAL PERFORMANCES OF TUBULAR HEAT EXCHANGERS BY USING WIRE-COIL INSERTS"
ICHMT DIGITAL LIBRARY ONLINE, Vol.1, 2000, issue
Bogosav Vasijevic, Rade Milenkovic
THERMAL VISUALIZATION AND PERFORMANCE EVALUATION OF THE OPEN MATRIX STRUCTURES USING LIQUID CRYSTAL THERMOGRAPHY
Journal of Flow Visualization and Image Processing, Vol.25, 2018, issue 3-4
Andallib Tariq, Anjana Prajapati
SINGLE PHASE LIQUID JET IMPINGEMENT COOLING OF SMALL HEAT SOURCES
International Heat Transfer Conference 9, Vol.4, 1990, issue
Satish Ramadhyani , D.J. Womac, G. Aharoni, Frank P. Incropera