Volume 27, 2020 Volume 26, 2019 Volume 25, 2018 Volume 24, 2017 Volume 23, 2016 Volume 22, 2015 Volume 21, 2014 Volume 20, 2013 Volume 19, 2012 Volume 18, 2011 Volume 17, 2010 Volume 16, 2009 Volume 15, 2008 Volume 14, 2007 Volume 13, 2006 Volume 12, 2005 Volume 11, 2004 Volume 10, 2003 Volume 9, 2002 Volume 8, 2001 Volume 7, 2000 Volume 6, 1999 Volume 5, 1998 Volume 4, 1997 Volume 3, 1996 Volume 2, 1995 Volume 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.v18.i4.30
pages 281-293

THERMOHYDRAULICS OF TURBULENT FLOW THROUGH SQUARE AND RECTANGULAR DUCTS WITH TRANSVERSE RIBS AND TWISTED TAPES WITH AND WITHOUT OBLIQUE TEETH

Sujoy Saha
WBUT & AICTE

RESUMO

Thermal and friction characteristics of turbulent flow through square and rectangular ducts with periodic transverse ribs and different types of twisted tapes with and without oblique teeth have been studied experimentally. Circular ducts have also been used. Correlations for predicting the friction factor and the Nusselt number have been developed and performance has been evaluated. Although both the friction factor and the Nusselt number are higher for all types of twisted tapes with oblique teeth in combination with transverse ribs, the performance evaluation has shown that the ducts with transverse ribs and regularly spaced twisted-tape elements with oblique teeth are better than those in the case without oblique teeth and this is recommended. Also, since the pressure drop in a heat exchanger is a small fraction of the total system pressure drop, the heat transfer being higher, full-length and short-length twisted tapes with oblique teeth in combination with transverse ribs can be recommended since the heat exchanging surface area requirement will be less.


Articles with similar content:

Thermal and Friction Characteristics of Laminar Flow through Square and Rectangular Ducts with Transverse Ribs and Twisted Tapes with and without Oblique Teeth
Journal of Enhanced Heat Transfer, Vol.17, 2010, issue 1
Sujoy Saha, P. K. Pal
NUMERICAL PREDICTIONS OF PRESSURE DROP AND HEAT TRANSFER IN A BLADE INTERNAL COOLING PASSAGE WITH CONTINUOUS/TRUNCATED RIBS
Heat Transfer Research, Vol.43, 2012, issue 6
Bengt Sunden, Gongnan Xie, Weihong Zhang, Shian Li
RELATIVE THERMO-HYDRAULIC PERFORMANCE OF DUCTS OF SQUARE AND CIRCULAR CROSS SECTIONS WITH TWISTED TAPE INSERTS
International Heat Transfer Conference 11, Vol.13, 1998, issue
Anil W. Date, S. Ray
IMPROVEMENT OF HEAT EXCHANGE IN A VENTILATED DOUBLE WALL TO INCREASE SUMMER COMFORT IN A TIMBER-FRAME HOUSE
ICHMT DIGITAL LIBRARY ONLINE, Vol.13, 2008, issue
Jean-Luc Kouyoumji, Raphael Boichot, Bernard Souyri, Gilles Fraisse
A Numerical Study of Fluid and Heat Transfer Performance of Heat Exchangers with Novel Short-Circuit Prevention Helical Baffles
International Heat Transfer Conference 15, Vol.23, 2014, issue
Wenjing Du, Hongfu Wang, Gongming Xin, Lin Cheng