Inscrição na biblioteca: Guest
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa
Journal of Enhanced Heat Transfer
Fator do impacto: 1.406 FI de cinco anos: 1.075 SJR: 0.287 SNIP: 0.653 CiteScore™: 1.2

ISSN Imprimir: 1065-5131
ISSN On-line: 1563-5074

Volumes:
Volume 27, 2020 Volume 26, 2019 Volume 25, 2018 Volume 24, 2017 Volume 23, 2016 Volume 22, 2015 Volume 21, 2014 Volume 20, 2013 Volume 19, 2012 Volume 18, 2011 Volume 17, 2010 Volume 16, 2009 Volume 15, 2008 Volume 14, 2007 Volume 13, 2006 Volume 12, 2005 Volume 11, 2004 Volume 10, 2003 Volume 9, 2002 Volume 8, 2001 Volume 7, 2000 Volume 6, 1999 Volume 5, 1998 Volume 4, 1997 Volume 3, 1996 Volume 2, 1995 Volume 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.v11.i4.180
pages 407-416

A Novel Micro Cooling System for Electronic Devices Using a Micro Capillary Groove Evaporator

Xuegong Hu
Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100190, China
Y. H. Zhao
Institute of Engineering Thermophysics, Chinese Academy of Sciences, P.O. Box 2706, Beijing 100080, P.R. China
Xiaohong Yan
Institute of Engineering Thermophysics, Chinese Academy of Sciences, P.O. Box 2706, Beijing 100080, P.R. China
Takaharu Tsuruta
Kyushu Institute of Technology, Sensui 1-1, Tobata, Kitakyushu, Fukuoka 804-8550, Japan

RESUMO

In the presented study, a novel micro cooling system for electronic devices using a micro capillary groove evaporator was proposed. Based on experimental data in open (atmospheric) condition, we found that liquid level has an obvious influence on evaporating heat flux. For a given liquid level, there exists an optimum groove size, which maximizes evaporation heat transfer capacity. By using the optimum groove sizes in the open condition, two types of closed cooling systems for CPU chips for personal computers were designed: one was for desktop models and the other for notebook models. Their cooling performance to keep CPU chip temperature below 90 °C reached 3.35 × 105 W/m2 and 2.51 × 105 W/m2, respectively, for the desktop model by using ethanol and the notebook model by using methanol. Experimental results show that the maximum cooling capacities strongly depend on the condensation capacities of condensers in the closed cooling systems and volume fractions of working liquid in the evaporators.


Articles with similar content:

EFFECTS OF CROSS-SECTION GEOMETRY ON THE THERMAL PERFORMANCE OF A PULSATING HEAT PIPE
First Thermal and Fluids Engineering Summer Conference, Vol.15, 2015, issue
Sungwan Park, Jungseok Lee, Sung Jin Kim
CFD ANALYSIS OF A WICKLESS HEAT PIPE
Proceedings of the 24th National and 2nd International ISHMT-ASTFE Heat and Mass Transfer Conference (IHMTC-2017), Vol.0, 2017, issue
Jeevan Jaidi, Sagar Singhal, Abhishek Gaikwad
CONSTRAINED VAPOR BUBBLE HEAT EXCHANGER
International Heat Transfer Conference 11, Vol.16, 1998, issue
M. Karthikeyan, Peter C. Wayner, Jr., J. Huang, Joel L. Plawsky
COOLING SYSTEM FOR HERMETIC COMPRESSOR BASED ON THE LOOP THERMOSYPHON
Heat Pipe Science and Technology, An International Journal, Vol.1, 2010, issue 4
Valery A. Aliakhnovich, Leonard L. Vasiliev
ADVANCED ANALYSIS OF AN AMMONIA LOOP HEAT PIPE FOR SPACE APPLICATIONS. PART I: THE NUMERICAL MODEL
Heat Pipe Science and Technology, An International Journal, Vol.4, 2013, issue 1-2
Stefano Zinna, Marco Molina, Claudio Ferrandi, Marco Marengo