Inscrição na biblioteca: Guest
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa
Journal of Enhanced Heat Transfer
Fator do impacto: 1.406 FI de cinco anos: 1.075 SJR: 0.287 SNIP: 0.653 CiteScore™: 1.2

ISSN Imprimir: 1065-5131
ISSN On-line: 1563-5074

Volumes:
Volume 27, 2020 Volume 26, 2019 Volume 25, 2018 Volume 24, 2017 Volume 23, 2016 Volume 22, 2015 Volume 21, 2014 Volume 20, 2013 Volume 19, 2012 Volume 18, 2011 Volume 17, 2010 Volume 16, 2009 Volume 15, 2008 Volume 14, 2007 Volume 13, 2006 Volume 12, 2005 Volume 11, 2004 Volume 10, 2003 Volume 9, 2002 Volume 8, 2001 Volume 7, 2000 Volume 6, 1999 Volume 5, 1998 Volume 4, 1997 Volume 3, 1996 Volume 2, 1995 Volume 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.v24.i1-6.320
pages 587-607

A REVIEW ON ENHANCED HEAT TRANSFER CHARACTERISTICS OF SINGLE-PHASE FLOWS IN A PLATE HEAT EXCHANGER

Arun Muley
Department of Mechanical, Industrial and Nuclear Engineering University of Cincinnati, Cincinnati, OH 45221-0072
Raj M. Manglik
Thermal-Fluids and Thermal Processing Laboratory, Mechanical and Materials Engineering, University of Cincinnati, 2600 Clifton Ave, Cincinnati, OH 45220, USA

RESUMO

The enhanced thermal-hydraulic performance of single-phase flows in a plate heat exchanger with mixed chevron plates is investigated experimentally. The mixed arrangement consists of plates with chevron angle β = 30° and 60°, alternatingly stacked in a single-pass, U-type, counterflow configuration. Vegetable oil (130 < Pr < 220) and water (2.4 < Pr < 4.5) are used as test fluids, with flow rates in the laminar, transition, and turbulent flow regimes (2 < Re < 6000). Results for isothermal friction factor and heat transfer under cooling conditions, along with respective correlations for laminar (2 < Re < 400) and fully developed turbulent (Re ≥ 1000) flows are presented; transition is observed to set in when Re ∼ 500. The heat transfer data are obtained from controlled experiments, employing an extension of the Wilson Plot technique. A comparison of the data with previously reported results and predictive equations for Nu and / highlights the latter’s lack of general applicability, and the need for a larger database. The relative impact of using mixed chevron plate arrangement is discussed, and their enhanced performance, in comparison with parallel-plate channels, is evaluated.


Articles with similar content:

Enhanced Heat Transfer Characteristics of Single-Phase Flows in a Plate Heat Exchanger with Mixed Chevron Plates
Journal of Enhanced Heat Transfer, Vol.4, 1997, issue 3
Raj M. Manglik, Arun Muley
STUDY ON HEAT TRANSFER PERFORMANCES OF CIRCUMFERENTIAL OVERLAP TRISECTION HELICAL BAFFLE HEAT EXCHANGERS
Heat Transfer Research, Vol.48, 2017, issue 4
Wei-Han Wang, Tao Liu, Ya-Ping Chen, Dao-Lai Cheng
FREE CONVECTIVE HEAT TRANSFER IN THE SUPERCRITICAL REGION
International Heat Transfer Conference 5, Vol.4, 1974, issue
Erich Hahne, Ulrich Grigull, G. Feurstein
Compound heat transfer enhancement by a combination of spirally corrugated tubes with a twisted tape
International Heat Transfer Conference 12, Vol.47, 2002, issue
Ventsislav D. Zimparov, Valentin Metodiev Petkov
PERFORMANCE CHARACTERISTICS OF DEEP CORRUGATED TUBES WITH TWISTED-TAPE INSERTS
Journal of Enhanced Heat Transfer, Vol.19, 2012, issue 1