INFLUENCE OF VOLTAGE FLUCTUATIONS RELATED TO PLASMA TORCH WORKING CONDITIONS ON ZIRCONIA PARTICLE THERMAL TREATMENT

E. Nogues
SPCTS Laboratory, University of Limoges, 123 av A. Thomas, 87060 Limoges Cedex; and BOC Edwards, 224 bd J. Kennedy, 91105 Corbeil-Essonnes Cedex, France
Michel Vardelle
LMCTS-URA 320, University of Limoges, 123 Avenue Albert Thomas -87060 Limoges Cedex - France
Pierre Fauchais
Laboratoire Sciences des Procedes Ceramiques et de Traitements de Surface UMR CNRS 6638 University of Limoges 123 avenue Albert Thomas, 87060 LIMOGES - France
P. Granger
BOC Edwards, 224 bd J. Kennedy, 91105 Corbeil-Essonnes Cedex, France

RESUMO

The microstructure of plasma sprayed coatings is strongly linked to particle trajectories depending among other parameters on arc root fluctuations. The latters depend on the torch anode-nozzle shape and internal diameter, the plasma forming gas composition and flow rate, and the anode erosion.
Experiments were performed with yttria partially stabilized zirconia (8 wt% yttria) particles with a size distribution between 5 to 25 μm and either a PTF4 or a 3MB GE Sulzer-Metco torch. The PTF4 torch was fed with an Ar-Mb mixture and an arc current of 600 A, while the 3MB torch was fed with N2-H2 mixture with an arc current of 500 A. Particle mean temperatures and mean velocities were measured to evaluate the influence of voltage fluctuations on the treatment.
This study shows that the torch working parameters, except the arc current, have nearly the same effects on the arc voltage fluctuations for the both torches. The 3MB torch voltage fluctuations are more important than those for a PTF4 torch, but they are less affected by the variations of spray parameters. Furthermore, the fluctuations of particle temperatures and velocities versus the voltage fluctuations are not the same.


Articles with similar content:

INFLUENCE OF POWDER SIZE DISTRIBUTIONS ON MICROSTRUCTURAL FEATURES OF FINELY STRUCTURED PLASMA SPRAYED COATINGS
High Temperature Material Processes: An International Quarterly of High-Technology Plasma Processes, Vol.8, 2004, issue 3
J. F. Coudert, J. Fazilleau, C. Delbos, C. Bonhomme, Pierre Fauchais, V. Rat
FROM TRANSFERRED ARC TO PLASMA TORCHES
High Temperature Material Processes: An International Quarterly of High-Technology Plasma Processes, Vol.9, 2005, issue 2
J. F. Coudert, C. Chazelas, D. Rigot, V. Rat
MODELLING OF THE INFLUENCE OF IRON AND ALUMINA PARTICLES ON A DC PLASMA TORCH
Progress in Plasma Processing of Materials, 1997, Vol.1, 1997, issue
J. J. Gonzalez, Pierre Proulx, J. M. Bauchire
MACROSCOPIC TECHNIQUES FOR RF. PLASMA REACTOR DIAGNOSTICS
Progress in Plasma Processing of Materials, 1997, Vol.1, 1997, issue
R. Diemiaszonek, C. Trassy, M. Garnier, O. Chazot
IDENTIFICATION OF LOCAL AND GLOBAL OSCILLATIONS IN A PLAS~A JET
Progress in Plasma Processing of Materials, 1999, Vol.1, 1999, issue
V. Nenicka, J. Hlina