Inscrição na biblioteca: Guest
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa
Plasma Medicine
SJR: 0.278 SNIP: 0.183 CiteScore™: 0.57

ISSN Imprimir: 1947-5764
ISSN On-line: 1947-5772

Plasma Medicine

DOI: 10.1615/PlasmaMed.2016015851
pages 1-12

The Use of an Atmospheric Pressure Plasma Jet to Inhibit Common Wound-Related Pathogenic Strains of Bacteria

Emilia M Kulaga
Plasmology4, Inc., Scottsdale, AZ
David J. Jacofsky
The CORE Institute, Phoenix, AZ
Courtney McDonnell
Plasmology4, Inc., Scottsdale, AZ
Marc C. Jacofsky
Plasmology4, Inc., Scottsdale, AZ; The CORE Institute, Phoenix, AZ

RESUMO

The Plaz4 electrosurgical generator produces a nonequilibrium atmospheric pressure plasma jet (APPJ) at 26°C. This APPJ was tested for its antibacterial capabilities on common wound-related pathogens. The inhibition zone (IZ) of bacterial growth and surviving colony-forming units (CFUs) within the IZ were determined for 4 common clinical isolates: Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa, and Acinetobacter baumannii. Agar was inoculated at a high density with a bacterial culture medium (107 CFUs/mL). The strains' susceptibility to the APPJ was tested at exposure times between 30 and 140 seconds. A positive correlation between plasma exposure time and bacterial growth IZ size, and a negative correlation between exposure time and the number of surviving CFUs inside the IZ, were observed. It was possible to achieve a round IZ, 4 cm in diameter, for all strains after 70 seconds of exposure, with less than 10 CFUs/cm2 surviving within the zone. P. aeruginosa was more resistant to plasma and required a longer exposure to achieve an IZ similar to that of other strains. However, the number of CFUs surviving inside the IZ was smaller for this strain for a majority of test conditions. Intraoperative contamination is a significant cause of perioperative infection. Drug-resistant bacteria are endemic to hospitals and are a significant public health concern. With the increasing risk of infections related to drug-resistant bacteria, it is crucial to look for alternative treatments. Electrosurgical generators are routinely used in surgical cases. Therefore, Plaz4 applied to surgical sites or debrided wounds could result in a clinically meaningful reduction in tissue bioburden.


Articles with similar content:

A Pilot Study of Atmospheric Nonthermal Plasma Jet Application on Staphylococcus aureus and Staphylococcus epidermidis
Plasma Medicine, Vol.2, 2012, issue 4
Jilu Shen, Chunjun Yang, Cheng Cheng, Shengxiu Liu, Wenhui Du, Shi Chen, Longdan Liu, Shumei Zhang, Jing Gao, Jie Shen, Shenghai Huang
Bactericidal Efficacy of Dielectric Barrier Discharge Plasma on Methicillin-Resistant Staphylococcus aureus and Escherichia coli in Planktonic Phase and Colonies In vitro
Plasma Medicine, Vol.5, 2015, issue 1
Halim Ayan, Niloofar Sanaei
Low-Temperature Plasma: An Effective Approach Against Candida albicans Biofilm
Plasma Medicine, Vol.4, 2014, issue 1-4
Xi Wei, Myrella Lessio Castro, Wirley Goncalves Assuncao, Simone Duarte, Ramiro Mendonca Murata, Juliana Aparecida Delben, Nelson Renato Franca Alves da Silva
In Vitro and In Vivo Analysis of Hydrogen Peroxide-Enhanced Plasma-Induced Effluent for Infection and Contamination Mitigation at Research and Medical Facilities
Plasma Medicine, Vol.5, 2015, issue 2-4
Mark Golkowski, Bruce McCollister, S. Reed Plimpton, Jori Leszczynski, Czeslaw Golkowski
Socket Preservation and Implant Insertion in a Smoker With a 10-Year History of Bisphosphonate Use: A Case Report
Journal of Long-Term Effects of Medical Implants, Vol.20, 2010, issue 4
Sebastiano Andreana, Carla Beneduce, Sasikumar Sunkara