Inscrição na biblioteca: Guest
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa
Atomization and Sprays
Fator do impacto: 1.737 FI de cinco anos: 1.518 SJR: 0.814 SNIP: 1.18 CiteScore™: 2.2

ISSN Imprimir: 1044-5110
ISSN On-line: 1936-2684

Volumes:
Volume 30, 2020 Volume 29, 2019 Volume 28, 2018 Volume 27, 2017 Volume 26, 2016 Volume 25, 2015 Volume 24, 2014 Volume 23, 2013 Volume 22, 2012 Volume 21, 2011 Volume 20, 2010 Volume 19, 2009 Volume 18, 2008 Volume 17, 2007 Volume 16, 2006 Volume 15, 2005 Volume 14, 2004 Volume 13, 2003 Volume 12, 2002 Volume 11, 2001 Volume 10, 2000 Volume 9, 1999 Volume 8, 1998 Volume 7, 1997 Volume 6, 1996 Volume 5, 1995 Volume 4, 1994 Volume 3, 1993 Volume 2, 1992 Volume 1, 1991

Atomization and Sprays

DOI: 10.1615/AtomizSpr.v18.i6.30
pages 511-522

FLOW-ADAPTED DESIGN OPTION FOR FREE-FALL ATOMIZERS

C. Czisch
University Bremen, Chemical Engineering Departmen, Badgasteiner Str. 3 D-28359 Bremen, Germany
Udo Fritsching
Department of Particles and Process Engineering, University of Bremen; Foundation Institute of Materials Science, Badgasteiner Str. 3, D-28359 Bremen, Germany

RESUMO

Free-fall gas atomizers are often used for liquid solution and melt atomization in the area of powder production and spray forming applications. This external mixing atomizer often uses two separate gas nozzle systems, namely, a primary gas nozzle (for prevention of major gas recirculation flow in the atomization area) and a secondary gas nozzle (for atomization), both concentrically surrounding the central liquid jet. Due to this specific arrangement, the atomization area is separated from the atomizer body, however the primary and secondary gas pressures need to be carefully adjusted. To improve the free-fall atomizer construction and operating conditions, the gas flow field of a conventional free-fall atomizer was investigated by numerical simulations. Aim of the investigation was to economize the primary gas application, while safely operating the atomizer without recirculations. Advantages of the derived flow-adapted atomizer design are a reduction in gas consumption, as well as the potential of generation of smaller particles. This effect was proven by atomization of a viscous melt.


Articles with similar content:

THEORETICAL STUDY OF THE COMBINED M-CYCLE/EJECTOR AIR-CONDITIONING SYSTEM
International Journal of Energy for a Clean Environment, Vol.12, 2011, issue 2-4
Sergiy V. Artemenko, Yehor Sladkovskyi, Andrei Chamchine, Olexiy Buyadgie, Dmytro Buyadgie, Oleksii Drakhnia
GAS FLOW EFFECTS ON TWIN-FLUID ATOMIZATION OF LIQUID METALS
Atomization and Sprays, Vol.10, 2000, issue 1
Ulrich Heck, Udo Fritsching, Klaus Bauckhage
ATOMIZATION OF VISCOUS MELTS
Atomization and Sprays, Vol.15, 2005, issue 2
C. Czisch, P. Schreckenberg, Udo Fritsching, H. Lohner, Klaus Bauckhage
SPRAY EVOLUTION IN A TWIN-FLUID SWIRL ATOMIZER
Atomization and Sprays, Vol.18, 2008, issue 5
J. Karnawat, Abhijit Kushari
Design of High Efficiency Aggregate Air Cooling System
Second Thermal and Fluids Engineering Conference, Vol.35, 2017, issue
Tareq Barham, Abdulla N. Olimat, Nabeel Abu Shaban, Malik I. Alamayreh