Inscrição na biblioteca: Guest
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa
Atomization and Sprays
Fator do impacto: 1.262 FI de cinco anos: 1.518 SJR: 0.814 SNIP: 1.18 CiteScore™: 1.6

ISSN Imprimir: 1044-5110
ISSN On-line: 1936-2684

Volumes:
Volume 29, 2019 Volume 28, 2018 Volume 27, 2017 Volume 26, 2016 Volume 25, 2015 Volume 24, 2014 Volume 23, 2013 Volume 22, 2012 Volume 21, 2011 Volume 20, 2010 Volume 19, 2009 Volume 18, 2008 Volume 17, 2007 Volume 16, 2006 Volume 15, 2005 Volume 14, 2004 Volume 13, 2003 Volume 12, 2002 Volume 11, 2001 Volume 10, 2000 Volume 9, 1999 Volume 8, 1998 Volume 7, 1997 Volume 6, 1996 Volume 5, 1995 Volume 4, 1994 Volume 3, 1993 Volume 2, 1992 Volume 1, 1991

Atomization and Sprays

DOI: 10.1615/AtomizSpr.v4.i3.60
pages 325-349

BOUNDARY-LAYER STRIPPING EFFECTS ON DROPLET TRANSCRITICAL CONVECTIVE VAPORIZATION

Jean-Pierre Delplanque
UC Davis
William A. Sirignano
Department of Mechanical and Aerospace Engineering, University of California at Irvine, USA

RESUMO

Previous studies have shown that the surface temperature of a liquid oxygen (LOX) droplet vaporizing in a supercritical quiescent environment reaches the computed critical mixture value; therefore, a model for supercritical combustion is needed. The purpose of this work is to investigate convective effects. A spherically symmetric model is constructed with an extension of the film model for the gas phase. The energy equation in the droplet is solved numerically and the high-pressure phase equilibrium is computed from the chemical potential equality for each component in each phase, using the Redlich-Kwong equation of state. Because of the reduced surface tension, the droplet undergoes mass removal from its surface by aerodynamic shearing (boundary-layer stripping). It is shown that, in a rocket engine, a LOX droplet is likely to undergo boundary-layer stripping for most of its lifetime. A simple integral analysis of the coupled gas−liquid boundary layers at the droplet interface yields an expression for the mass removal rate that includes blowing effects and that is shown to be much larger than the vaporization rate. The effect of stripping on the heat transfer into the droplet is evaluated with a modified film model. Results show that, in most cases, stripping precludes criticality at the interface. Computations also show that stripping reduces the predicted droplet lifetime by at least one order of magnitude, thus affecting significantly the range of frequencies in which the gasification process might be driving combustion instabilities. The computed droplet lifetime is compared to the expressions available in the literature. The sensitivity of the predicted droplet behavior to the threshold value of the stripping breakup criterion is demonstrated.


Articles with similar content:

CUBIC AND MULTIPARAMETER EQUATIONS OF STATE EVALUATION FOR SUPERCRITICAL FLOW MODELING
4th Thermal and Fluids Engineering Conference, Vol.30, 2019, issue
Andre R. R. Silva, Eduardo Antunes, Jorge M. M. Barata, Leandro Magalhães
INFLUENCE OF LATERAL CONTROL SYSTEM ON TRANSPORT AIRCRAFT SPIN
TsAGI Science Journal, Vol.49, 2018, issue 1
Alexander Nikolaevich Khrabrov, Maria Evguenievna Sidoryuk, Diana Aleksandrovna Alieva
NUMERICAL INVESTIGATION OF STABILITY AND EVOLUTION OF AN EVAPORATING LIQUID FILM ON A HEATED STRUCTURED WALL
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2017, issue
Tatiana Gambaryan-Roisman, Peter Stephan, Achim Bender
AXISYMMETRIC CALCULATIONS OF THREE-DROPLET INTERACTIONS
Atomization and Sprays, Vol.3, 1993, issue 1
C. H. Chiang, William A. Sirignano
THE MECHANISMS INVOLVED IN THE COMBUSTION OF A LIQUID OXIDIZER CAPSULE CONTAINED IN A SOLID FUEL
International Journal of Energetic Materials and Chemical Propulsion, Vol.7, 2008, issue 6
Avishag D. Pelosi, Alon Gany