DOI: 10.1615/ICHMT.2006.TurbulHeatMassTransf
ISBN Print: 978-1-56700-229-4
ISSN: 2377-2816
Flow Field and Reynolds Stress Distribution in Low Turbulence Natural Convection in a Triangular Cavity
ABSTRACT
Triangular enclosures are typical configurations found in attic spaces of residential as well as industrial pitched-roof buildings. Previous studies on airflow within such spaces have focused on the laminar range. A numerical study has been carried out for time-dependent, two-dimensional low turbulence natural convection of air contained in the attic of a pitched roof of triangular cross-section. Two sets of boundary conditions have been considered: enclosure heated from the inclined walls and from the horizontal base wall, for aspect ratios (AR) of 0.33 ≤ AR ≤ 1.73 for Rayleigh number (Ra), 109 ≤ Ra ≤ 1011. In this paper, the flow field and Reynolds stress distribution are presented for the isothermal and isoflux cases.